{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00050303-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00050303-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00050303-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00050303-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS530 series, AC drive, 3ABD00050303-D, 315 kW output, 585 A normal use, 380-480 V 3-phase, Frame R10, IP00, IE2.","salesMarkdown":"The ABB 3ABD00050303-D is an ACS530-04-585A-4 drive delivering 315 kW output at 585 A normal use, with a light-overload rating of 575 A at the same power. It runs on 380-480 V three-phase, 47.5-63 Hz, and is built as a cabinet-mounted unit (no enclosure) with IP00 protection and NEMA Open Type construction. The frame size is R10, and standby loss sits at 396 W. The 585 A normal-use current (In) and 575 A light-overload current (IlD) are the numbers that decide the cable sizing and upstream protection for this drive. Both share the same 315 kW power output, so the overload margin is slim — the light-overload rating is essentially the same as normal use, meaning this drive is sized for continuous duty at its nameplate. The 405 kVA apparent power output confirms the transformer or line reactor needs to handle that throughput. Ambient temperature is capped at 40 °C; above that, derating applies. The IP00 open type means it goes into a panel or cabinet — no standalone weatherproofing.","metaTitle":"ABB 3ABD00050303-D ACS530 Drive, 315 kW, 585 A, Frame R10","metaDescription":"ABB ACS530-04-585A-4 drive, 315 kW output, 585 A normal use, 380-480 V 3-phase. Frame R10, IP00, IE2. Active lifecycle, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R10","Standby Loss":"396 W","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Cabinet-built","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP00","Apparent Power Output":"405 kV·A","Output Power, Normal Use (Pn)":"315 kW","Output Current, Normal Use (In)":"585 A","Output Power, Light-Overload Use (PlD)":"315 kW","Output Current, Light-Overload Use (IlD)":"575 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00050303-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00050303-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of 3ABD00050303-D?","answer":"The frame size is R10, which determines the physical mounting footprint and cabinet cutout dimensions for this drive."},{"question":"What is the standby loss for this drive?","answer":"Standby loss is 396 W. This is the heat dissipated when the drive is powered but not running a motor — relevant for cabinet cooling and ventilation sizing."},{"question":"What compliance documentation is available for this drive?","answer":"The drive carries WEEE Category 5 classification (Small Equipment). For RoHS, REACH, and UL documentation, these are standard for ABB ACS530 drives and can be provided with the order upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00050303-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00050303-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}