{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00050631","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00050631","canonicalUrl":"https://aoctrl.com/abb/3ABD00050631","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00050631","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS380-040C-09A4-4+K490, LV AC machinery drive module, 4 kW / 9.4 A normal use, 380-480 V three-phase, Frame R1, IP20, IE2.","salesMarkdown":"The ABB 3ABD00050631 is the order code for an LV AC machinery drive module. It delivers 4 kW normal-use output at 9.4 A, with a heavy-duty rating of 3 kW at 7.2 A. The normal-use 4 kW / 9.4 A rating is the headline for a standard constant-torque load like a conveyor or pump. If your BOM calls for a 4 kW motor on a light-duty cycle, the normal-use line is your spec; if the application is a heavy start or cyclic overload, the heavy-duty number is the binding one. The light-overload rating (4 kW / 8.9 A) sits between them and matches the normal-use power with a slightly lower current — useful when the thermal profile is moderate but not constant. Frame size R1 is the mechanical envelope. It tells the panel builder which mounting footprint and gland-plate layout to expect. IE2 efficiency is the baseline for the region this drive is deployed in. It is not a premium-efficiency class.","metaTitle":"ABB 3ABD00050631 ACS380 Drive, 4 kW, 9.4 A, Frame R1","metaDescription":"ABB ACS380-040C-09A4-4+K490 drive module, 4 kW normal use, 9.4 A, 380-480 V three-phase, frame R1, IP20, IE2. Active lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R1","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"4 kW","Output Current, Normal Use (In)":"9.4 A","Output Power, Heavy-Duty Use (PhD)":"3 kW","Output Current, Heavy-Duty Use (IhD)":"7.2 A","Output Power, Light-Overload Use (PlD)":"4 kW","Output Current, Light-Overload Use (IlD)":"8.9 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00050631","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00050631/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of the 3ABD00050631?","answer":"The frame size is R1."},{"question":"What input voltage and frequency does it accept?","answer":"Three-phase 380-480 V, 47.5-63 Hz."},{"question":"What are the normal-use and heavy-duty output ratings?","answer":"Normal use: 4 kW, 9.4 A. Heavy duty: 3 kW, 7.2 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00050631","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00050631 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}