{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00057911","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00057911","canonicalUrl":"https://aoctrl.com/abb/3ABD00057911","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00057911","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS380 machinery drive module, frame R2, 380-480 V 3-phase, 5.5 kW / 12.6 A normal duty, IP20, IE2.","salesMarkdown":"## What this drive module is The ABB 3ABD00057911 is an ACS380-series machinery drive module in frame size R2, built for 380...480 V three-phase input. It delivers 5.5 kW at 12.6 A under normal-duty use, with a heavy-duty rating of 4.0 kW at 9.4 A for tougher loads. The IP20 open-type enclosure means it's meant for cabinet mounting, not out in the weather. Efficiency lands at IE2, which is the baseline for this class. The normal-duty current of 12.6 A is the number to match against your motor's full-load amps for constant-torque applications like conveyors or pumps. If you're sizing for a heavier cyclic load — say a crusher or a centrifuge — the heavy-duty curve at 9.4 A is the one that governs. There's also a light-overload rating of 12.0 A at 5.5 kW, which covers variable-torque fans and blowers where peak demand is short. The 47.5...63 Hz input frequency range means it handles both 50 Hz and 60 Hz mains without derating.","metaTitle":"ABB 3ABD00057911 ACS380 Drive Module, 5.5 kW, 12.6 A","metaDescription":"ABB ACS380 frame R2 drive module, 5.5 kW / 12.6 A normal duty, 380-480 V 3-phase, IP20, IE2. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"5.5 kW","Output Current, Normal Use (In)":"12.6 A","Output Power, Heavy-Duty Use (PhD)":"4.0 kW","Output Current, Heavy-Duty Use (IhD)":"9.4 A","Output Power, Light-Overload Use (PlD)":"5.5 kW","Output Current, Light-Overload Use (IlD)":"12.0 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00057911","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00057911/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R2. That's the physical mounting footprint and heat-sink size for this power level."},{"question":"What's the difference between the normal-duty and heavy-duty ratings?","answer":"Normal duty is 5.5 kW / 12.6 A for constant-torque loads. Heavy duty drops to 4.0 kW / 9.4 A for more demanding cyclic or overload-prone applications. Use the heavy-duty figure if your motor sees repeated peak current."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00057911","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00057911 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}