{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00057952","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00057952","canonicalUrl":"https://aoctrl.com/abb/3ABD00057952","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00057952","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS380-040C-09A4-4+K470+L515+L535, LV AC machinery drive module, 4 kW / 9.4 A normal use, frame size R1, IP20, IE2.","salesMarkdown":"The 3ABD00057952: Heavy-duty use is rated 3.0 kW at 7.2 A; light-overload use is 4.0 kW at 8.9 A. The normal-use 9.4 A figure is the one to size by for continuous motor duty — the heavy-duty number governs for constant-torque loads like conveyors or mixers where the drive must hold torque through intermittent overloads.","metaTitle":"ABB 3ABD00057952 ACS380 Drive Module, 4 kW, 9.4 A","metaDescription":"ABB 3ABD00057952 ACS380-040C-09A4-4+K470+L515+L535 LV AC drive module. 4 kW normal use, 9.4 A output, IP20, IE2. Active production. Frame size R1. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R1","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"4 kW","Output Current, Normal Use (In)":"9.4 A","Output Power, Heavy-Duty Use (PhD)":"3.0 kW","Output Current, Heavy-Duty Use (IhD)":"7.2 A","Output Power, Light-Overload Use (PlD)":"4.0 kW","Output Current, Light-Overload Use (IlD)":"8.9 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00057952","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00057952/alternatives.json"},"ai":{"faq":[{"question":"What is 3ABD00057952's listed frame size?","answer":"Frame size R1."},{"question":"What is the input voltage and frequency range?","answer":"Input voltage is 380–480 V three-phase, frequency range 47.5–63 Hz."},{"question":"What are the output ratings for normal, heavy-duty, and light-overload use?","answer":"Normal use: 4 kW, 9.4 A. Heavy-duty use: 3.0 kW, 7.2 A. Light-overload use: 4.0 kW, 8.9 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00057952","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00057952 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}