{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00058056-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00058056-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00058056-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00058056-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS530-01-039A-4+P972, frame R3, 18.5 kW / 39 A, IP20, 380-500 V 3-phase.","salesMarkdown":"The ABB 3ABD00058056-D is an ACS530-01-039A-4+P972 drive in frame size R3, rated for 18.5 kW normal-use output with 39 A continuous current on a 380-500 V 3-phase supply. Light-overload duty drops to 36 A at the same 18.5 kW — enough headroom for modest surge profiles without upsizing the frame. Compared to the next-smaller R2 frame, the R3 here carries roughly 30% more continuous current at the same voltage band, so if your motor load is 15 kW with a high-inertia start the R3 keeps the I²t margin without stepping to an R4 enclosure. Wall-mounted open-type enclosure rated IP20. Frequency range 47.5 to 63 Hz covers both 50 Hz and 60 Hz line supplies without derating. The R3 frame footprint fits a standard 400 mm wide backplate; allow 100 mm clearance above and below for airflow.","metaTitle":"ABB 3ABD00058056-D ACS530-01-039A-4+P972, 18.5 kW, 39 A","metaDescription":"ABB ACS530-01-039A-4+P972 drive, 18.5 kW output, 39 A, 380-500 V 3-phase, IP20, active lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R3","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","lifecycle_stage":"current","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"18.5 kW","Output Current, Normal Use (In)":"39 A","Output Power, Light-Overload Use (PlD)":"18.5 kW","Output Current, Light-Overload Use (IlD)":"36 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00058056-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00058056-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of 3ABD00058056-D?","answer":"Frame size R3."},{"question":"What is the input voltage and frequency range?","answer":"380-500 V 3-phase, 47.5-63 Hz."},{"question":"What is the output power and current rating?","answer":"18.5 kW normal-use output at 39 A; light-overload rating is 18.5 kW at 36 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00058056-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00058056-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}