{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00058057-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00058057-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00058057-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00058057-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS530-01-046A-4+P972, 22 kW normal-use output, 46 A output current, 380-500 V 3-phase input, IP20, frame size R3.","salesMarkdown":"The ABB 3ABD00058057-D is an ACS530-01-046A-4+P972 drive rated for 22 kW normal-use output at 46 A, fed from a 380-500 V 3-phase supply. Frame size R3, IP20, open-type enclosure — wall-mount ready for panel integration.","metaTitle":"ABB 3ABD00058057-D ACS530-01-046A-4+P972, 22 kW, 46 A","metaDescription":"ABB ACS530-01-046A-4+P972 drive, 22 kW normal-use output, 46 A output current, 380-500 V 3-phase input, IP20, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R3","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","lifecycle_stage":"current","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"22 kW","Output Current, Normal Use (In)":"46 A","Output Power, Light-Overload Use (PlD)":"22 kW","Output Current, Light-Overload Use (IlD)":"42.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00058057-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00058057-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of 3ABD00058057-D?","answer":"Frame size R3."},{"question":"What is the input voltage and frequency range?","answer":"Input voltage is 380-500 V 3-phase, frequency range 47.5-63 Hz."},{"question":"What is the output power and current rating?","answer":"Normal-use output power is 22 kW at 46 A; light-overload rating is 22 kW at 42.8 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00058057-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00058057-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}