{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00058711-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00058711-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00058711-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00058711-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB LV AC wall-mounted drive, Frame R1, 0.75 kW, 2.6 A, 380-500 V, 3-phase, IP20, NEMA Open Type.","salesMarkdown":"The ABB 3ABD00058711-D is a low-voltage AC wall-mounted drive in Frame R1, rated 0.75 kW normal-use output at 2.6 A, with light-overload capability at 0.75 kW and 2.5 A. It accepts 380-500 V three-phase input across 47.5-63 Hz, and carries IP20 protection in a NEMA Open Type enclosure. The normal-use current of 2.6 A at 0.75 kW is the rating that governs motor sizing — it matches a standard 1 hp (0.75 kW) induction motor on 400 VAC. The light-overload current (2.5 A) is essentially the same curve, so the drive doesn't give you extra headroom for short-duration overloads; it's sized for continuous HVAC duty. Frame R1 means the drive body is compact enough to mount on a wall plate or inside a small panel, but the IP20 rating says keep it in a clean environment — no washdown or outdoor exposure. ## Mounting & wiring notes Wall-mounted, open type — no separate enclosure needed if the drive sits in a controlled electrical room. The 47.5-63 Hz frequency acceptance means it handles 50 Hz and 60 Hz supplies without configuration. Three-phase input, so land, L2, L3; the motor output terminals connect to the motor leads. Ground bond per local code; use a torque driver on the power terminals — the frame R1 terminal block is small, and overtightening strips the threads.","metaTitle":"ABB 3ABD00058711-D LV AC Drive, Frame R1, 0.75 kW, 2.6 A","metaDescription":"ABB 3ABD00058711-D LV AC wall-mounted drive, 0.75 kW, 2.6 A, 380-500 V, IP20, NEMA Open Type. Active production, sourced to order. Frame R1, 3-phase, 47.5-63 Hz.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R1","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","lifecycle_stage":"current","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"0.75 kW","Output Current, Normal Use (In)":"2.6 A","Output Power, Light-Overload Use (PlD)":"0.75 kW","Output Current, Light-Overload Use (IlD)":"2.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00058711-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00058711-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame R1 — the smallest mechanical size in the ACH531 series, suitable for 0.75 kW output."},{"question":"What compliance documentation is available?","answer":"The drive is listed as a standard ABB LV AC drive; RoHS, REACH, and CE documentation is typically provided with the shipment. Specific UL or IEC certificates should be confirmed at time of order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00058711-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00058711-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}