{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00059486-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00059486-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00059486-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00059486-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-01, LV AC industrial wall-mounted single drive with position control, 1.5 kW / 3.4 A normal use, 380-500 V, IP21, Frame Size R1.","salesMarkdown":"The ABB 3ABD00059486-D is an ACS880-01 wall-mounted drive rated 1.5 kW normal use (3.4 A) on 380-500 V three-phase input, 48-63 Hz. Heavy-duty use drops to 1.1 kW / 3 A; light-overload use stays at 1.5 kW / 3.2 A. Frame size R1, IP21 open-type enclosure. Position control is built in — no extra option card needed for basic indexing or encoder feedback.","metaTitle":"ABB 3ABD00059486-D ACS880-01 Drive, 1.5 kW, 3.4 A, IP21","metaDescription":"ABB ACS880-01 drive (3ABD00059486-D), 1.5 kW normal use, 3.4 A, 380-500 V, IP21 wall-mount. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R1","Frequency (f)":"48 ... 63 Hz","Mounting Type":"Wall-mounted","lifecycle_stage":"current","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"1.5 kW","Output Current, Normal Use (In)":"3.4 A","Output Power, Heavy-Duty Use (PhD)":"1.1 kW","Output Current, Heavy-Duty Use (IhD)":"3 A","Output Power, Light-Overload Use (PlD)":"1.5 kW","Output Current, Light-Overload Use (IlD)":"3.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00059486-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00059486-D/alternatives.json"},"ai":{"faq":[{"question":"Can you confirm the output current at heavy-duty rating?","answer":"Yes: at 1.1 kW heavy-duty use (PhD), the output current is 3 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00059486-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00059486-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}