{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00059492-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00059492-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00059492-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00059492-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-01 series, LV AC industrial wall-mounted single drive with position control, 3ABD00059492-D, 11 kW normal use, 21 A, 380-500 V, 3-phase, IP21, frame size R2.","salesMarkdown":"## Drive selection memo The ABB 3ABD00059492-D is an ACS880-01-021A-5+N5700 wall-mounted drive rated for 11 kW normal use at 21 A on a 380-500 V three-phase supply. The heavy-duty rating drops to 7.5 kW at 14 A, and the light-overload rating holds at 11 kW but at 19 A — the normal-use figure is the one to size a constant-torque fan or pump against, while the heavy-duty curve governs for a conveyor or extruder with short peak loads. Frame size R2 and IP21 enclosure suit a clean indoor panel or wall-mount location. For a BOM line that needs the integrated position control (the +N5700 option), this is the exact variant to specify.","metaTitle":"ABB 3ABD00059492-D ACS880-01-021A-5+N5700, 11 kW, 21 A","metaDescription":"ABB ACS880-01 drive, 3ABD00059492-D, 11 kW normal use, 21 A, 380-500 V, 3-phase, IP21, wall-mounted, active lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R2","Frequency (f)":"48 ... 63 Hz","Mounting Type":"Wall-mounted","lifecycle_stage":"current","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"11 kW","Output Current, Normal Use (In)":"21 A","Output Power, Heavy-Duty Use (PhD)":"7.5 kW","Output Current, Heavy-Duty Use (IhD)":"14 A","Output Power, Light-Overload Use (PlD)":"11 kW","Output Current, Light-Overload Use (IlD)":"19 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00059492-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00059492-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of 3ABD00059492-D?","answer":"Frame size R2."},{"question":"What are the normal-use and heavy-duty ratings?","answer":"Normal use: 11 kW at 21 A. Heavy-duty use: 7.5 kW at 14 A. Light-overload use: 11 kW at 19 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00059492-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00059492-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}