{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00059529-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00059529-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00059529-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00059529-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-01 wall-mounted single drive, 3-phase, 380-500 V, 30 kW / 52 A normal duty, Frame R4, IP21, IE2.","salesMarkdown":"The 3ABD00059529-D: The drive carries three output ratings: light-overload (PlD) at 30 kW / 49 A, normal use (Pn) at 30 kW / 52 A, and heavy-duty (PhD) at 22 kW / 40 A. The heavy-duty figure governs applications like conveyors, crushers, or extruders where the motor draws sustained high torque. For variable-torque loads (fans, pumps), the normal-use 52 A gives you headroom. IE2 efficiency level applies across the operating range. Wall-mounted, IP21, NEMA Type 1 enclosure — suitable for indoor, non-condensing environments. Frame size R4 determines the physical footprint and gland-plate layout; verify backplate dimensions and cable entry spacing before panel layout.","metaTitle":"ABB 3ABD00059529-D ACS880-01 Drive, 30 kW, 52 A, Frame R4","metaDescription":"ABB 3ABD00059529-D ACS880-01 wall-mounted drive, 30 kW / 52 A normal duty, IP21, IE2. Active production. Frame R4. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R4","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"30 kW","Output Current, Normal Use (In)":"52 A","Output Power, Heavy-Duty Use (PhD)":"22 kW","Output Current, Heavy-Duty Use (IhD)":"40 A","Output Power, Light-Overload Use (PlD)":"30 kW","Output Current, Light-Overload Use (IlD)":"49 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00059529-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00059529-D/alternatives.json"},"ai":{"faq":[{"question":"What are the key output ratings for this drive?","answer":"Normal-duty output is 30 kW at 52 A; heavy-duty output is 22 kW at 40 A. Light-overload rating is 30 kW at 49 A."},{"question":"What frame size and enclosure does this drive have?","answer":"Frame size R4, wall-mounted, IP21, NEMA Type 1."},{"question":"What input voltage and frequency does it accept?","answer":"380–500 V, 47.5–63 Hz, three-phase."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00059529-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00059529-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}