{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00059719-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00059719-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00059719-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00059719-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB, ACS880-04 series, LV AC industrial single drive module with position control, Frame R11, 380–500 V, 3-phase, 48–63 Hz, 630 kW / 880 A normal duty, IP20, Open Type.","salesMarkdown":"The ABB 3ABD00059719-D is a single drive module rated 630 kW normal duty at 880 A, with heavy-duty capability at 500 kW / 697 A and light-overload at 560 kW / 857 A. The normal-duty 880 A is the figure you size the input cabling and upstream protection for. Heavy-duty 697 A applies when the load demands constant torque across the speed range — conveyors, extruders, positive-displacement pumps. Light-overload 857 A suits variable-torque loads like centrifugal pumps and fans where peak current only appears during acceleration. All three ratings share the same Frame R11 hardware; the difference is the thermal model the drive uses for overload protection.","metaTitle":"ABB 3ABD00059719-D ACS880-04 Drive Module, 630 kW / 880 A, F","metaDescription":"Active ABB ACS880-04 single drive module, 380–500 V, 3-phase, 630 kW normal / 880 A. Frame R11, IP20. Sourced to order; RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R11","Frequency (f)":"48 ... 63 Hz","Mounting Type":"Module","lifecycle_stage":"current","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"630 kW","Output Current, Normal Use (In)":"880 A","Output Power, Heavy-Duty Use (PhD)":"500 kW","Output Current, Heavy-Duty Use (IhD)":"697 A","Output Power, Light-Overload Use (PlD)":"560 kW","Output Current, Light-Overload Use (IlD)":"857 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00059719-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00059719-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive module?","answer":"Frame R11. That determines the mounting footprint, busbar spacing, and cabinet cutout dimensions for the ACS880-04 platform."},{"question":"How do I source this drive module?","answer":"It's an active, current-production part. Submit an RFQ for lead time and pricing; we quote to order through the ABB channel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00059719-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00059719-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}