{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00061620-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00061620-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00061620-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00061620-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS510, Frame R6, 75 kW normal use, 145 A output current, 380-480 V, 3-phase, IP20, wall-mounted.","salesMarkdown":"The ABB 3ABD00061620-D is an ACS510 drive in Frame R6, rated for 75 kW normal-use output at 145 A continuous, with heavy-duty capability at 55 kW / 105 A and light-overload at 75 kW / 138 A. Input is 380-480 V three-phase, 47.5-63 Hz. IP20 enclosure, wall-mounted, NEMA Open Type. IE2 efficiency class. Active in production. Three current ratings let you match the drive to the load profile. Normal use (145 A) covers constant-torque applications like conveyors or pumps running at full load. Heavy-duty (105 A) is for high-starting-torque loads — crushers, extruders, mixers — where the drive must deliver peak current without tripping. Light-overload (138 A) suits variable-torque fans and centrifugal pumps where overload duration is short. Wall-mounted, IP20 for clean indoor panels. NEMA Open Type means it needs a cabinet for dust and moisture protection. Frame R6 is a larger footprint — verify backplate dimensions and clearance for airflow before committing the panel layout.","metaTitle":"ABB 3ABD00061620-D ACS510 Drive, 75 kW, 145 A, Frame R6","metaDescription":"ABB ACS510 drive 3ABD00061620-D, 75 kW normal use, 145 A output, 380-480 V, 3-phase, IP20, wall-mounted, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R6","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"75 kW","Output Current, Normal Use (In)":"145 A","Output Power, Heavy-Duty Use (PhD)":"55 kW","Output Current, Heavy-Duty Use (IhD)":"105 A","Output Power, Light-Overload Use (PlD)":"75 kW","Output Current, Light-Overload Use (IlD)":"138 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00061620-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00061620-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame R6."},{"question":"What are the key output ratings?","answer":"Normal use: 75 kW, 145 A. Heavy-duty: 55 kW, 105 A. Light-overload: 75 kW, 138 A."},{"question":"What input voltage and frequency does it accept?","answer":"380-480 V three-phase, 47.5-63 Hz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00061620-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00061620-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}