{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD50000039037","brand":"ABB","brandSlug":"abb","productSlug":"3ABD50000039037","canonicalUrl":"https://aoctrl.com/abb/3ABD50000039037","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD50000039037","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01 series, LV AC wall-mounted drive, 4 kW normal use, 9.4 A output, 380-500 V 3-phase, IP55, NEMA 12, IE2.","salesMarkdown":"The ABB 3ABD50000039037 is a wall-mounted drive rated for 4 kW normal use at 9.4 A output, on a 380-500 V 3-phase supply. It carries IP55 protection and a NEMA Type 12 enclosure, so it handles dust and hose-down in water/wastewater environments without an extra cabinet. The drive lists three output curves. Normal use delivers 4 kW at 9.4 A — that is the continuous rating for a standard centrifugal pump or fan load. Light-overload use sits at 4 kW at 8.9 A, a middle curve for applications with modest overloads. The IE2 efficiency level means the drive meets the minimum efficiency standard for variable-speed operation in most regions.","metaTitle":"ABB 3ABD50000039037 ACQ580-01 Drive, 4 kW, 9.4 A, IP55","metaDescription":"ABB ACQ580-01 wall-mounted drive, 4 kW normal use, 9.4 A output, 380-500 V 3-phase input. IP55, NEMA 12, IE2. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R1","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"Product Not in WEEE Scope","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP55","Output Power, Normal Use (Pn)":"4 kW","Output Current, Normal Use (In)":"9.4 A","Output Power, Heavy-Duty Use (PhD)":"3 kW","Output Current, Heavy-Duty Use (IhD)":"7.2 A","Output Power, Light-Overload Use (PlD)":"4 kW","Output Current, Light-Overload Use (IlD)":"8.9 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd50000039037","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD50000039037/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R1, which determines the physical mounting footprint and the available options slot."},{"question":"What are the normal-use and heavy-duty output ratings?","answer":"Normal use: 4 kW at 9.4 A. Heavy-duty use: 3 kW at 7.2 A. Light-overload use: 4 kW at 8.9 A."},{"question":"What enclosure protection does it have?","answer":"IP55 and NEMA Type 12, suitable for dust and hose-down environments without an extra cabinet."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD50000039037","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD50000039037 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}