{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ADT218042S0132","brand":"ABB","brandSlug":"abb","productSlug":"3ADT218042S0132","canonicalUrl":"https://aoctrl.com/abb/3ADT218042S0132","factsUrl":"https://aoctrl.com/api/mcp/products/3ADT218042S0132","rawCanonicalId":null},"summary":{"shortDescription":"ABB DCS880-S01-2500-05 DC converter, 2Q, 525 VAC, 2500 A, frame H7, 180 kg, 75 dB(A).","salesMarkdown":"The ABB 3ADT218042S0132 is a DCS880-S01-2500-05 DC converter — a 2-quadrant unit rated for 525 VAC input and 2500 A output, in frame size H7. It handles continuous DC motor armature supply for drives that don't need regenerative braking, so the field supply or a separate braking chopper handles the deceleration energy. The 2500 A is the continuous output current at the rated 525 VAC supply. Sound level is 75 dB(A). The auxiliary terminals carry an IP00 rating per IEC 60529, IEC 60947-1, and EN 60529. That means the terminal block area is open — no finger-safe covers. In a panel build, those terminals need to be behind a locked door or a separate guard, not exposed on a live panel. ## Integration notes The DCS880-S01-2500-05 is a 2Q converter — it delivers power in one direction only. If the motor needs to regenerate (overhauling load, fast deceleration), you need an external braking resistor or a 4Q unit. The frame H7 has dedicated terminals for the DC bus and the field supply; the three analog inputs and two analog outputs cover speed reference, current feedback, and a spare for temperature monitoring. Operating humidity range is 5 to 95 % RH — no condensation allowed. Line frequency is 50 Hz.","metaTitle":"3ADT218042S0132 ABB DCS880-S01-2500-05 DC Converter, 525 VAC","metaDescription":"ABB DCS880-S01-2500-05 DC converter, 525 VAC input, 2500 A output, 2Q, frame H7, 75 dB(A). Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["DC Drives"],"specifications":{"Frame Size":"H7","Sound dB (A)":"75 dB(A)","Analog Inputs":"3","Frequency (f)":"50 Hz","Analog Outputs":"2","lifecycle_stage":"current","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP00","Operating Humidity (RHamβ)":"5...95%"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3adt218042s0132","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ADT218042S0132/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this DC converter?","answer":"Frame size H7. That determines the physical footprint, mounting hole pattern, and bus bar arrangement for the DC output and AC input connections."},{"question":"What is the sound level of this drive?","answer":"75 dB(A) at rated load. This is the audible noise from the cooling fans and magnetics inside the H7 frame. Plan for enclosure sound damping if the drive is near personnel for extended periods."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ADT218042S0132","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ADT218042S0132 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}