{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ADT218587S0113","brand":"ABB","brandSlug":"abb","productSlug":"3ADT218587S0113","canonicalUrl":"https://aoctrl.com/abb/3ADT218587S0113","factsUrl":"https://aoctrl.com/api/mcp/products/3ADT218587S0113","rawCanonicalId":null},"summary":{"shortDescription":"ABB DCS880-S01-0900-06 DC Converter, 2Q, 600 VAC, 0900 A, Frame Size H6, 73 dB(A), 3 analog inputs, 2 analog outputs.","salesMarkdown":"The 3ADT218587S0113: The 73 dB(A) sound level is the in-service noise emission at rated load. If the converter sits in a quiet control room or near operator stations, factor in acoustic enclosure treatment or remote mounting. The IP00 rating on auxiliary terminals (per IEC 60529, IEC 60947-1, EN 60529) means those terminals are unprotected against solid objects and moisture — the converter must be installed inside a suitable cabinet with at least IP54 to keep dust and conductive debris off the control wiring. Three analog inputs and two analog outputs are available. The 50 Hz line frequency is fixed. ## Installation and compliance notes Operating humidity range of 5 to 95% RH covers most indoor industrial environments. Mount the converter close to the line entry to keep DC bus inductance low.","metaTitle":"3ADT218587S0113 ABB DCS880-S01-0900-06 DC Converter, 600 VAC","metaDescription":"ABB DCS880-S01-0900-06 DC converter, 600 VAC / 0900 A, 2Q, Frame H6, 73 dB(A). Active lifecycle. 3 analog inputs, 2 analog outputs. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"Frame Size":"H6","Sound dB (A)":"73 dB(A)","Analog Inputs":"3","Frequency (f)":"50 Hz","Analog Outputs":"2","lifecycle_stage":"current","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP00","Operating Humidity (RHamβ)":"5...95%"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3adt218587s0113","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ADT218587S0113/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this converter?","answer":"Frame size H6, which determines the mounting footprint and panel cutout dimensions."},{"question":"What is the sound level of this unit?","answer":"73 dB(A) at rated load. Plan for acoustic treatment if the converter is near operator stations."},{"question":"What compliance documentation is available?","answer":"ABB provides a declaration of conformity and CE marking per the DCS880 series technical file. The IP00 rating on auxiliary terminals means the converter requires an enclosure for protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ADT218587S0113","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ADT218587S0113 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}