{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ADT218587S0122","brand":"ABB","brandSlug":"abb","productSlug":"3ADT218587S0122","canonicalUrl":"https://aoctrl.com/abb/3ADT218587S0122","factsUrl":"https://aoctrl.com/api/mcp/products/3ADT218587S0122","rawCanonicalId":null},"summary":{"shortDescription":"ABB DCS880-S01-1200-05 DC converter, Frame H6, 1200 A, 525 VAC, 2-quadrant, 110 kg.","salesMarkdown":"The ABB 3ADT218587S0122 is a DCS880-S01-1200-05 DC converter — a 2-quadrant unit rated for 1200 A at 525 VAC input, in Frame H6. That puts it in the heavy end of the DCS880 line, sized for large DC motor drives or regenerative loads where you need controlled DC output from a three-phase AC supply. Three analog inputs and two analog outputs are available for speed reference, current feedback, or process signals — enough for a basic drive control loop without an external I/O block. Sound level is listed at 73 dB(A) — that's the fan noise at full load. In a control room or quiet production area, factor that into the ambient noise budget.","metaTitle":"3ADT218587S0122 ABB DCS880-S01-1200-05 DC Converter, 1200 A,","metaDescription":"ABB 3ADT218587S0122 DCS880-S01-1200-05 DC converter, 1200 A, 525 VAC, 2-quadrant, Frame H6. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["DC Drives"],"specifications":{"Frame Size":"H6","Sound dB (A)":"73 dB(A)","Analog Inputs":"3","Frequency (f)":"50 Hz","Analog Outputs":"2","lifecycle_stage":"current","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP00","Operating Humidity (RHamβ)":"5...95%"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3adt218587s0122","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ADT218587S0122/alternatives.json"},"ai":{"faq":[{"question":"What is the sound level of this unit?","answer":"73 dB(A) at full load, driven by the internal cooling fans."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ADT218587S0122","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ADT218587S0122 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}