{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ADT218587S0144","brand":"ABB","brandSlug":"abb","productSlug":"3ADT218587S0144","canonicalUrl":"https://aoctrl.com/abb/3ADT218587S0144","factsUrl":"https://aoctrl.com/api/mcp/products/3ADT218587S0144","rawCanonicalId":null},"summary":{"shortDescription":"ABB DCS880-S01-2000-07 DC converter, 2Q, 690 VAC, 2000 A, frame size H6, 73 dB(A).","salesMarkdown":"The 3ADT218587S0144: The 2000 A continuous rating at 690 VAC input defines the converter's capacity for feeding DC bus or motor armature loads in heavy industrial drives. Frame H6 dictates the mechanical footprint and cooling requirements — expect a large cabinet-mount unit with forced air or liquid cooling provisions. The 73 dB(A) sound level is typical for a converter of this power class; plan for hearing protection if the drive is in a manned area. The IP00 protection on auxiliary terminals means the main enclosure must provide the environmental seal — these terminals are live and require panel-level guarding. ## Integration notes Mount the converter in a ventilated cabinet with clearance for the H6 frame's airflow path. The 3 analog inputs and 2 analog outputs are available for speed reference, current feedback, or process signals — wire with shielded twisted-pair, grounded at one end. The 50 Hz supply is fixed; for 60 Hz networks, verify the DC link capacitor bank rating with the factory. Auxiliary terminals are IP00 — terminate in an enclosed junction box or within the panel's protected volume.","metaTitle":"ABB 3ADT218587S0144 DCS880 DC Converter, 2000 A, 690 VAC, Fr","metaDescription":"Active ABB DCS880 DC converter, 2000 A, 690 VAC, frame size H6, 2Q, 73 dB(A). 3 analog inputs, 2 analog outputs. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"Frame Size":"H6","Sound dB (A)":"73 dB(A)","Analog Inputs":"3","Frequency (f)":"50 Hz","Analog Outputs":"2","lifecycle_stage":"current","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP00","Operating Humidity (RHamβ)":"5...95%"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3adt218587s0144","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ADT218587S0144/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size H6?","answer":"Frame size H6 is the mechanical and thermal rating envelope for this DCS880 converter, corresponding to the 2000 A / 690 VAC power stage. It determines mounting dimensions, busbar layout, and cooling requirements."},{"question":"What does the 73 dB(A) sound level mean for installation?","answer":"At 73 dB(A), the converter is audible in a control room. For continuous operator exposure, hearing protection or a remote cabinet location should be considered per local noise regulations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ADT218587S0144","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ADT218587S0144 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}