{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AUD0000000072","brand":"ABB","brandSlug":"abb","productSlug":"3AUD0000000072","canonicalUrl":"https://aoctrl.com/abb/3AUD0000000072","factsUrl":"https://aoctrl.com/api/mcp/products/3AUD0000000072","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-series HVAC drive with integrated circuit breaker disconnect, 3-phase 380-480 V, UL light-overload 350 Hp / 414 A, NEMA Type 3R enclosure, 50/60 Hz.","salesMarkdown":"The ABB 3AUD0000000072 is an ACH580-series HVAC drive with an integrated circuit breaker disconnect, rated for 3-phase 380-480 V input at 50/60 Hz. Its UL light-overload rating of 350 Hp / 414 A means it can continuously supply a 3-phase induction motor of that size on a fan or pump curve without needing to oversize the drive for the starting current — the integrated breaker handles the branch-circuit protection upstream, so you skip a separate disconnect in the enclosure. NEMA Type 3R enclosure means this unit is rated for outdoor installation — rain-tight, sleet-resistant, and the enclosure won't corrode under a roof eave or on a rooftop pad. No separate weather hood needed for most commercial HVAC rooftop applications. The integrated circuit breaker disconnect is a single assembly; mount the drive, land the line-side power on the breaker lugs, and the load-side conductors terminate directly on the drive output bus.","metaTitle":"ABB 3AUD0000000072 HVAC Drive, 350 Hp, 414 A, NEMA 3R","metaDescription":"ABB 3AUD0000000072 HVAC drive with circuit breaker disconnect, 380-480 V 3-phase, 350 Hp / 414 A UL light-overload. Active production, quoted to order. NEMA 3R enclosure.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frequency (f)":"50/60 Hz","lifecycle_stage":"mature","Number of Phases":"3-phase","Enclosure Type NEMA":"Type3R","Input Voltage (Uin)":"380 ... 480 V","Technical UL/Output Power, Light-Overload Use (UL)":"350 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"414 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3aud0000000072","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AUD0000000072/alternatives.json"},"ai":{"faq":[{"question":"What is the input voltage and frequency for 3AUD0000000072?","answer":"Rated for 3-phase 380-480 V input at 50/60 Hz. The wide voltage window covers both 400 V and 480 V nominal systems without a reconnection tap."},{"question":"What is the UL light-overload rating for this drive?","answer":"UL light-overload rating is 350 Hp / 414 A. This is the continuous output capacity for variable-torque HVAC loads (fans, centrifugal pumps) under UL listing."},{"question":"Where can I buy 3AUD0000000072?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AUD0000000072","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AUD0000000072 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}