{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AUD0000003146","brand":"ABB","brandSlug":"abb","productSlug":"3AUD0000003146","canonicalUrl":"https://aoctrl.com/abb/3AUD0000003146","factsUrl":"https://aoctrl.com/api/mcp/products/3AUD0000003146","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580 series, HVAC packaged ultra-low harmonic drive with non-fused disconnect, 3-phase, 440-480 V input, 300 Hp light-overload at 460 V, 361 A output, Frame R11, IP21, NEMA Type 1.","salesMarkdown":"The ABB 3AUD0000003146 is an ACH580-series HVAC packaged drive delivering 300 Hp light-overload output at 460 V, with a continuous output current of 361 A per the UL listing. Input voltage range is 440 to 480 V three-phase at 50/60 Hz. The R11 frame size houses the non-fused disconnect and ultra-low harmonic filtering in a single enclosure. The 361 A light-overload rating at 460 V governs the motor current the drive can supply continuously without derating — sized for a 300 Hp induction motor on a fan or pump load profile. The 440-480 V input range covers 460 V nominal North American distribution; the 50/60 Hz rating confirms compatibility with both 50 Hz and 60 Hz line supplies. Frame R11 defines the mounting footprint, conduit entry locations, and bus bar spacing for panel integration. The non-fused disconnect integrated into the packaged drive provides a local lockable means of disconnection, reducing external component count in the panel. The drive carries an active lifecycle status per the manufacturer.","metaTitle":"ABB 3AUD0000003146 HVAC Drive, 300 Hp, 361 A, 460 V, R11","metaDescription":"ABB ACH580-3PDR-361A-4 HVAC ultra-low harmonic drive, 300 Hp light-overload at 460 V, 361 A output, IP21 NEMA 1, active production. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R11","Frequency (f)":"50/60 Hz","lifecycle_stage":"mature","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"440 ... 480 V","Degree of Protection":"IP21","Technical UL/Output Power, Light-Overload Use (UL)":"300 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"361 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3aud0000003146","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AUD0000003146/alternatives.json"},"ai":{"faq":[{"question":"What is 3AUD0000003146's listed frame size?","answer":"The frame size is R11."},{"question":"What is the input voltage and frequency for 3AUD0000003146?","answer":"Input voltage is 440 to 480 V three-phase at 50/60 Hz."},{"question":"What is the output power and current rating?","answer":"UL light-overload rating is 300 Hp at 460 V with 361 A continuous output current."},{"question":"What enclosure type does this drive have?","answer":"IP21 protection, NEMA Type 1 enclosure for indoor use."},{"question":"How do I get current pricing and availability for 3AUD0000003146?","answer":"Submit an RFQ; the drive is sourced to order through independent distribution with pricing and availability confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AUD0000003146","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AUD0000003146 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-14T23:38:33.845Z","lastPublished":"2026-09-14T23:38:33.845Z","indexable":true}}