{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AUD0000004270","brand":"ABB","brandSlug":"abb","productSlug":"3AUD0000004270","canonicalUrl":"https://aoctrl.com/abb/3AUD0000004270","factsUrl":"https://aoctrl.com/api/mcp/products/3AUD0000004270","rawCanonicalId":null},"summary":{"shortDescription":"ABB 3AUD0000004270 HVAC packaged drive with e-clipse bypass and circuit breaker disconnect, UL: Pld 60 Hp, 62 A, 500...600 V, 3-phase, 50/60 Hz, NEMA Type3R.","salesMarkdown":"## HVAC packaged drive with e-clipse bypass The ABB 3AUD0000004270 is an HVAC packaged drive combining a variable-frequency drive with an e-clipse bypass and a circuit breaker disconnect in a single NEMA Type3R enclosure. It's built for 3-phase 500... 600 V input at 50/60 Hz, and carries a UL light-overload rating of 60 Hp / 62 A — the number that governs motor sizing for UL-listed installations. The 62 A light-overload current (UL) is the continuous output the drive can deliver to a 60 Hp motor without tripping on overload — that's your sizing anchor. The 500... 600 V input range covers 480 V and 575 V nominal supplies common in North American industrial and commercial HVAC, but the drive's own minimum is 500 V, so a 480 V line is below the rated floor; verify your actual supply voltage against the 500 V minimum before specifying. NEMA Type3R means the enclosure is rainproof and sleet-resistant — suited for outdoor rooftop or wall-mounted HVAC installations where the drive sees weather but not hose-down. It's not a washdown rating; if the location gets hosed, you need Type4 or 4X. The NEMA Type3R packaged format includes the bypass and disconnect inside the same enclosure — no separate contactor, overload relay, or disconnect switch to panel-build around. That saves enclosure space and wiring labor on rooftop units or mechanical-room walls. The circuit breaker disconnect serves as both service-disconnect and branch-circuit protection, so the feeder only needs upstream short-circuit protection.","metaTitle":"ABB 3AUD0000004270 HVAC Packaged Drive, 60 Hp, 62 A, 500-600","metaDescription":"ABB 3AUD0000004270 HVAC packaged drive with e-clipse bypass and circuit breaker disconnect. UL rated 60 Hp, 62 A light-overload. 3-phase, 500-600 V input, NEMA Type3R. Active produ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"Frequency (f)":"50/60 Hz","lifecycle_stage":"mature","Number of Phases":"3-phase","Enclosure Type NEMA":"Type3R","Input Voltage (Uin)":"500 ... 600 V","Technical UL/Output Power, Light-Overload Use (UL)":"60 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"62 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3aud0000004270","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AUD0000004270/alternatives.json"},"ai":{"faq":[{"question":"What is the input voltage range for 3AUD0000004270?","answer":"The input voltage rating is 500... 600 V, 3-phase, 50/60 Hz. Note the 500 V minimum — a 480 V supply is below the rated floor."},{"question":"What is the UL output rating for this drive?","answer":"UL light-overload rating is 60 Hp and 62 A — that's the continuous output for motor sizing in UL-listed installations."},{"question":"Where can I buy 3AUD0000004270?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AUD0000004270","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AUD0000004270 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}