{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000031887","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000031887","canonicalUrl":"https://aoctrl.com/abb/3AXD50000031887","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000031887","rawCanonicalId":null},"summary":{"shortDescription":"ABB drive module, frame size R1, 0.75 kW normal use output, 380-480 V 3-phase input, IP20, MODBUS, IE2 efficiency.","salesMarkdown":"The ABB 3AXD50000031887 is a current-production drive module in frame size R1, rated for 0.75 kW normal-use output (2.6 A) on a 380-480 V three-phase supply. It includes the control unit and communicates via MODBUS. The IP20 enclosure suits panel-mount installations where the ambient temperature stays at or below 50 °C. Three duty ratings are defined: normal use at 0.75 kW / 2.6 A, light-overload at 0.75 kW / 2.5 A, and heavy-duty at 0.55 kW / 1.8 A. The heavy-duty figure governs continuous motor operation under high starting torque or frequent cycling. For UL-marked installations, the normal-use current is derated to 2.1 A, and heavy-duty power is 0.75 Hp at 1.6 A. The module provides 2 analog inputs and 1 analog output, plus 5 digital inputs and 2 digital outputs. No industrial Ethernet interface is fitted; MODBUS is the onboard protocol. Standby loss is 15 W, and full-load power consumption is 44 W.","metaTitle":"ABB 3AXD50000031887 Drive Module, 0.75 kW, 380-480 V, IP20","metaDescription":"ABB drive module 3AXD50000031887, 0.75 kW normal use, 380-480 V 3-phase input, IP20, MODBUS, IE2. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"df417ff4-f8a5-4aa8-b5b9-bb43623953af Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R1","Power Factor":"0.98","Sound dB (A)":"63.10 dB(A)","Standby Loss":"15 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"1","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"1.8 kV·A","Communication Protocol":"MODBUS","Power Consumption (@Pcons)":"44 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"5 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"0.75 kW","Output Current, Normal Use (In)":"2.6 A","Output Power, Heavy-Duty Use (PhD)":"0.55 kW","Output Current, Heavy-Duty Use (IhD)":"1.8 A","Output Power, Light-Overload Use (PlD)":"0.75 kW","Certificates and Declarations/RoHS Date":"20230303","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"2.5 A","Technical UL/Output Current, Normal Use (UL)":"2.1 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"0.75 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"1.6 A","Technical UL/Output Power, Light-Overload Use (UL)":"1 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"2.1 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000031887","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000031887/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does ABB provide for this drive?","answer":"RoHS compliance per EU Directive 2011/65/EU (date 20230303), REACH declaration with substances above 0.1% mass (date 20250905), and UL ratings for normal-use current (2.1 A), heavy-duty power (0.75 Hp), and heavy-duty current (1.6 A)."},{"question":"What is the SCIP number for this drive?","answer":"The SCIP number is df417ff4-f8a5-4aa8-b5b9-bb43623953af Finland."},{"question":"What is the maximum operating altitude?","answer":"1000 m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000031887","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000031887 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}