{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000031895","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000031895","canonicalUrl":"https://aoctrl.com/abb/3AXD50000031895","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000031895","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580 general purpose drive, 3AXD50000031895, R3 frame, 11 kW / 25 A normal use, 7.5 kW / 17 A heavy duty, 3-phase 380-480 V, IP20, MODBUS.","salesMarkdown":"The 3AXD50000031895: The 5 digital inputs and 2 digital outputs, plus 2 analog inputs and 1 analog output, cover basic I/O for a standalone pump or fan application without an expansion module. Standby loss sits at 26 W, and the maximum ambient is 50 °C — derate above that if the panel runs hot. The R3 frame is a common size for this power band; mounting is module-style on a backplate or DIN-rail adapter (not included). ## Heavy-duty vs normal-use ratings The drive carries three distinct output ratings: normal use (11 kW / 25 A), light-overload use (11 kW / 23.8 A), and heavy-duty use (7.5 kW / 17 A). Under UL listing, the normal-use current drops to 21 A, and heavy-duty output is 10 Hp / 14 A. The light-overload column (23.8 A) is for variable-torque fans and centrifugal pumps where peak demand stays brief. Rated for installation up to 1000 m altitude without derating. Operating humidity range is 5-95% RH (non-condensing). Sound pressure level is 65.8 dB(A) — noticeable in a quiet control room but typical for an R3 drive at full load. The WEEE category is 5 (small equipment under 50 cm), so end-of-life disposal routing is straightforward. Mount the module on a flat backplate with clearance for airflow; IP20 means no protection against water ingress, so keep it inside the panel.","metaTitle":"ABB 3AXD50000031895 ACS580 drive, R3 frame, 11 kW, 25 A","metaDescription":"ABB ACS580 drive, 3AXD50000031895, 11 kW / 25 A normal use, 7.5 kW / 17 A heavy duty, 3-phase 380-480 V, IP20, MODBUS, R3 frame, current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"df291eaa-8422-40ff-acd0-55c77c3d1d9f Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R3","Power Factor":"0.98","Sound dB (A)":"65.80 dB(A)","Standby Loss":"26 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"1","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"17 kV·A","Communication Protocol":"MODBUS","Power Consumption (@Pcons)":"390 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"5 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"11 kW","Output Current, Normal Use (In)":"25.0 A","Output Power, Heavy-Duty Use (PhD)":"7.5 kW","Output Current, Heavy-Duty Use (IhD)":"17.0 A","Output Power, Light-Overload Use (PlD)":"11.0 kW","Certificates and Declarations/RoHS Date":"20230303","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"23.8 A","Technical UL/Output Current, Normal Use (UL)":"21.0 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"10 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"14 A","Technical UL/Output Power, Light-Overload Use (UL)":"15 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"21 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000031895","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000031895/alternatives.json"},"ai":{"faq":[{"question":"What are the key output ratings for this drive?","answer":"Normal use: 11 kW / 25 A. Heavy-duty use: 7.5 kW / 17 A. Light-overload use: 11 kW / 23.8 A. UL normal use: 21 A; UL heavy-duty: 10 Hp / 14 A."},{"question":"What communication protocol does it support?","answer":"MODBUS is the onboard protocol. No Industrial Ethernet interface is included on this variant."},{"question":"What compliance documentation is available?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (date 2023-03-03). REACH declaration confirms substances above 0.1% (date 2025-09-05). SCIP number df291eaa-8422-40ff-acd0-55c77c3d1d9f (Finland). UL listing with separate current and horsepower ratings for normal and heavy-duty use."},{"question":"What is the frame size and mounting type?","answer":"Frame size R3. Mounting type is module — typically backplate-mounted; IP20 open-type enclosure."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000031895","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000031895 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}