{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000034622","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000034622","canonicalUrl":"https://aoctrl.com/abb/3AXD50000034622","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000034622","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01 LV AC drive, wall-mounted, 30 kW / 62 A normal use, 22 kW / 45 A heavy-duty, 380-480 V, IP55, frame R4.","salesMarkdown":"## Ratings that matter for cold-chain and pump loads The 3AXD50000034622: The heavy-duty current rating of 45 A is the number to size by if you're driving a refrigeration compressor or a variable-torque pump that sees occasional overloads. Normal-use 62 A covers constant-torque loads like fans or conveyors in a cold-store environment. Ambient temperature maxes out at 50 °C, which gives headroom even in a warm mechanical room. Altitude rating of 4000 m means no derating needed for most installations — only high-altitude plants above that need a check. The IP55 and NEMA Type 12 enclosure keeps out dust and hose-directed water, so it's at home on a wall near a washdown station or in a humid wastewater plant. Onboard communication is CAN; there are zero Industrial Ethernet interfaces on this variant. If you need Modbus TCP, PROFINET, or EtherNet/IP, you'll add an option module. The drive carries 6 digital inputs and 3 digital outputs, plus 2 analog inputs and 2 analog outputs — enough for basic pump control with feedback from a pressure transmitter.","metaTitle":"ABB 3AXD50000034622 ACQ580-01 drive, 30 kW, 62 A, IP55","metaDescription":"ABB ACQ580-01 wall-mounted drive, 30 kW / 62 A normal use, 22 kW / 45 A heavy-duty. IP55, 380-480 V, 3-phase. Active production. RoHS/REACH compliant. Order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"cdc24b2a-20d2-4e65-816b-a638fc9e9fb1 Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R4","Power Factor":"0.98","Sound dB (A)":"70 dB(A)","Standby Loss":"21 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP55","Apparent Power Output":"43 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"782 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"30 kW","Output Current, Normal Use (In)":"62 A","Output Power, Heavy-Duty Use (PhD)":"22 kW","Output Current, Heavy-Duty Use (IhD)":"45 A","Output Power, Light-Overload Use (PlD)":"30 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"58 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000034622","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000034622/alternatives.json"},"ai":{"faq":[{"question":"What is the enclosure rating and mounting type?","answer":"IP55 / NEMA Type 12, wall-mounted. Frame size R4."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000034622","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000034622 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}