{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000036413","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000036413","canonicalUrl":"https://aoctrl.com/abb/3AXD50000036413","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000036413","rawCanonicalId":null},"summary":{"shortDescription":"ABB, ACS880 series, LV AC machinery drive module, 3AXD50000036413, 30 kW, 61 A, 400 V, frame size R4, IP20.","salesMarkdown":"The 3AXD50000036413: The normal-use current of 61 A (IEC) is the continuous rating for standard duty cycles — that's the number to size the motor and the upstream protection against. Heavy-duty at 52 A covers applications with higher starting torque or frequent starts, like conveyors or crushers. Light-overload at 57 A splits the difference, useful for pumps and fans with modest overload profiles. The apparent power output of 42 kV·A gives you the transformer sizing ballpark for the input side. The SCIP number (68896070-a736-4d39-9ed9-c9264f7f4ba3 Finland) is the article identifier for the EU's waste framework database — it's the number your downstream user needs if they're submitting SCIP notifications for the end product.","metaTitle":"ABB 3AXD50000036413 ACS880 Drive Module, 30 kW, 61 A, R4","metaDescription":"ABB ACS880-M04-061A-5 drive module, 30 kW normal use, 61 A, 400 V, frame R4, IP20. Active production. RoHS/REACH compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"68896070-a736-4d39-9ed9-c9264f7f4ba3 Finland","Altitude":"1000 m","Includes":"PC connection","Frame Size":"R4","Power Factor":"0.98","Sound dB (A)":"70 dB(A)","Standby Loss":"34 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP20","Apparent Power Output":"42 kV·A","Communication Protocol":"CAN","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 2 pcs, 6 g","Number of Digital In/Outputs":"6 / 5","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"30 kW","Output Current, Normal Use (In)":"61 A","Output Power, Heavy-Duty Use (PhD)":"22 kW","Output Current, Heavy-Duty Use (IhD)":"52 A","Output Power, Light-Overload Use (PlD)":"30 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"57 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"40 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"52 A","Technical UL/Output Power, Light-Overload Use (UL)":"40 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"57 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000036413","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000036413/alternatives.json"},"ai":{"faq":[{"question":"What frame size is this drive module?","answer":"The frame size is R4, which determines the mounting footprint, busbar layout, and cable entry positions within the ACS880 family."},{"question":"Does this module include onboard I/O and communication?","answer":"Yes, it includes 2 analog inputs, 2 analog outputs, 6 digital inputs, and 5 digital outputs. Communication is CAN-based (CANopen). There are no onboard industrial Ethernet interfaces; an optional module is needed for PROFINET or EtherNet/IP."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000036413","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000036413 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}