{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000038970","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000038970","canonicalUrl":"https://aoctrl.com/abb/3AXD50000038970","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000038970","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01 wall-mounted drive, 5.5 kW / 12.6 A normal use, 380-480 V 3-phase, IP55, Type 12, frame R1.","salesMarkdown":"General-purpose wall-mounted drive, order code 3AXD50000038970, sized for a 5.5 kW motor at 12.6 A normal use on a 380-480 V three-phase supply. Heavy-duty use drops to 4.0 kW and 9.4 A. Frame size R1, IP55 / NEMA Type 12 enclosure. Efficiency is IE2 class. Normal-use output (Pn 5.5 kW, In 12.6 A) matches a standard 5.5 kW induction motor. Heavy-duty (PhD 4.0 kW, IhD 9.4 A) is for constant-torque loads. Light-overload use (PlD 5.5 kW, IlD 12.0 A) sits close to normal use. Input voltage range is 380-480 V, 47.5-63 Hz. ## Environment and mounting Rated for 50 °C maximum ambient, 95% RH non-condensing, and 1000 m altitude without derating. Above that altitude, standard derating applies. The IP55 / NEMA Type 12 enclosure means it's dust-tight and protected against hose-directed water — fine for food processing, wastewater, or outdoor installation under a roof. Wall-mounted, frame R1, so plan for gland plate access and clearance for the cooling fan intake. Standby loss is 14 W; sound level 59 dB(A). Two analog inputs, two analog outputs, six digital inputs, three digital outputs — enough for basic speed reference, start/stop, and fault feedback. Communication is CAN onboard; no built-in Ethernet, so if the line uses EtherNet/IP or PROFINET, an optional fieldbus adapter is needed. The control unit is included. A lithium coin cell (CR2032, 220 mAh) backs the real-time clock and parameter storage.","metaTitle":"ABB 3AXD50000038970 ACS580-01 Drive, 5.5 kW, IP55","metaDescription":"ABB ACS580-01 general-purpose drive, 5.5 kW, 12.6 A, 380-480 V, IP55, Type 12, IE2. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"85773b93-5c45-45c8-a538-ebdaaaf96ece Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R1","Sound dB (A)":"59 dB(A)","Standby Loss":"14 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP55","Apparent Power Output":"8.7 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"213 W","Operating Humidity (RHamβ)":"95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"5.5 kW","Output Current, Normal Use (In)":"12.6 A","Output Power, Heavy-Duty Use (PhD)":"4.0 kW","Output Current, Heavy-Duty Use (IhD)":"9.4 A","Output Power, Light-Overload Use (PlD)":"5.5 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"12.0 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000038970","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000038970/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive?","answer":"SCIP 85773b93-5c45-45c8-a538-ebdaaaf96ece, Finland."},{"question":"What compliance documentation is available?","answer":"RoHS (EU 2011/65/EU + 2015/863, dated 20240508) and REACH (contains substances >0.1 mass %, dated 20250905)."},{"question":"What is the difference between normal-use and heavy-duty ratings?","answer":"Normal use (Pn 5.5 kW, In 12.6 A) is for variable-torque loads like fans and pumps. Heavy-duty (PhD 4.0 kW, IhD 9.4 A) is for constant-torque applications such as conveyors or positive-displacement pumps."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000038970","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000038970 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}