{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000038981","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000038981","canonicalUrl":"https://aoctrl.com/abb/3AXD50000038981","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000038981","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-01 series, LV AC wall-mounted drive for HVAC, 3-phase, 380-480 V, 0.75 kW / 1 Hp, 2.6 A, IP21, BACnet, frame R1.","salesMarkdown":"The ABB 3AXD50000038981 is an ACH580-01-02A7-4 LV AC wall-mounted drive for HVAC applications. It delivers 0.75 kW normal-use output (Pn) at 2.6 A (In) on a 380–480 V three-phase supply, with a heavy-duty rating of 0.6 kW (PhD) at 1.8 A (IhD) and a light-overload rating of 0.75 kW (PlD) at 2.5 A (IlD). Under UL listing, light-overload output is 1 Hp at 2.1 A. Frame size R1, wall-mounted, IP21 with NEMA Type 1 enclosure. Ambient temperature max 40 °C, altitude 1000 m, humidity up to 95%. Standby loss is 14 W; sound level 59 dB(A). Built-in BACnet communication (no Industrial Ethernet interface). Analog I/O: 2 inputs, 2 outputs. Digital I/O: 6 inputs, 3 outputs. Includes a control unit and a CR2032 lithium coin cell for backup. Efficiency class IE2. Power consumption at rated load is 44 W; apparent power output is 1.8 kV·A. Frequency range 47.5–63 Hz. SCIP number a5c3dd71-8ecd-44d9-98e4-45c53b6836e1 Finland is on file for EU waste reporting. WEEE category 5 (small equipment). ## Sourcing This is an active, current-production ABB drive. No direct pin-compatible alternative exists — the R1 frame is specific to this power band.","metaTitle":"ABB 3AXD50000038981 ACH580-01 VFD, 0.75 kW, 2.6 A, 380-480 V","metaDescription":"ABB ACH580-01-02A7-4 VFD, 0.75 kW / 1 Hp, 2.6 A, IP21, BACnet. Active lifecycle, RoHS/REACH compliant. Sourced to order. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"a5c3dd71-8ecd-44d9-98e4-45c53b6836e1 Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R1","Sound dB (A)":"59 dB(A)","Standby Loss":"14 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP21","Apparent Power Output":"1.8 kV·A","Communication Protocol":"BACNET","Power Consumption (@Pcons)":"44 W","Operating Humidity (RHamβ)":"95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"0.75 kW","Output Current, Normal Use (In)":"2.6 A","Output Power, Heavy-Duty Use (PhD)":"0.6 kW","Output Current, Heavy-Duty Use (IhD)":"1.8 A","Output Power, Light-Overload Use (PlD)":"0.75 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"2.5 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"1.6 A","Technical UL/Output Power, Light-Overload Use (UL)":"1 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"2.1 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000038981","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000038981/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive?","answer":"The SCIP number is a5c3dd71-8ecd-44d9-98e4-45c53b6836e1 Finland."},{"question":"What compliance documentation is available?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (date 20240508). REACH declaration (date 20250905) confirms substances above 0.1 mass percentage. UL listing covers heavy-duty output at 1.6 A and light-overload at 1 Hp / 2.1 A."},{"question":"What is the altitude rating?","answer":"The drive is rated for installation at altitudes up to 1000 m."},{"question":"What are the key output ratings?","answer":"Normal use: 0.75 kW at 2.6 A. Heavy-duty: 0.6 kW at 1.8 A. Light-overload: 0.75 kW at 2.5 A. UL light-overload: 1 Hp at 2.1 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000038981","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000038981 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}