{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000038999","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000038999","canonicalUrl":"https://aoctrl.com/abb/3AXD50000038999","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000038999","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-01 series, LV AC wall-mounted HVAC drive, 3AXD50000038999, 1.1 kW normal use, 3.3 A, 380-480 V, IP55, BACnet, frame size R1.","salesMarkdown":"## Drive for HVAC applications — BACnet, IP55, frame R1 Rated 1.1 kW normal use (3.3 A) on a 380–480 V three-phase supply, it delivers 2.3 kVA apparent power. The IP55 enclosure and NEMA Type 12 rating let it mount directly on a wall in washdown or dusty mechanical rooms without a separate cabinet. Communication is BACnet over the built-in port — no optional module needed. That makes it a straight drop into a BMS backbone for fan, pump, or compressor control. There are 2 analog inputs and 2 analog outputs for sensor feedback or setpoint trim, plus 6 digital inputs and 3 digital outputs for start/stop, fault reset, or status indication. ## Duty ratings — normal, heavy, light overload This drive carries three output ratings so you match the load profile without oversizing. Normal use (IEC) is 1.1 kW / 3.3 A; heavy-duty use drops to 0.8 kW / 2.6 A for constant-torque loads like conveyors or positive-displacement pumps. Light-overload use holds at 1.1 kW / 3.1 A — same power as normal but slightly lower current, reflecting a different duty cycle. Under UL listing the light-overload rating is 1.5 Hp / 3.0 A, and heavy-duty UL drops to 2.1 A. Pick the rating that matches your motor's service factor and the application's peak demand. Frame size R1, wall-mounted. Ambient temperature limit is 40 °C maximum; operating humidity up to 95% RH non-condensing. Standby loss is 14 W, and full-load power consumption is 51 W. The drive includes a control unit and a lithium coin cell (CR2032, 220 mAh) for real-time clock backup. No industrial Ethernet interface is present — BACnet is the only fieldbus on board.","metaTitle":"ABB 3AXD50000038999 ACH580-01 HVAC Drive, 1.1 kW, IP55","metaDescription":"Active ABB ACH580-01 HVAC drive, 3AXD50000038999. 1.1 kW normal use, 3.3 A, 380-480 V, IP55, BACnet, RoHS/REACH compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"85773b93-5c45-45c8-a538-ebdaaaf96ece Finland","Includes":"With control unit","Frame Size":"R1","Standby Loss":"14 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP55","Apparent Power Output":"2.3 kV·A","Communication Protocol":"BACNET","Power Consumption (@Pcons)":"51 W","Operating Humidity (RHamβ)":"95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6/3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"1.1 kW","Output Current, Normal Use (In)":"3.3 A","Output Power, Heavy-Duty Use (PhD)":"0.8 kW","Output Current, Heavy-Duty Use (IhD)":"2.6 A","Output Power, Light-Overload Use (PlD)":"1.1 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"3.1 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"2.1 A","Technical UL/Output Power, Light-Overload Use (UL)":"1.5 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"3.0 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000038999","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000038999/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive?","answer":"The SCIP number is 85773b93-5c45-45c8-a538-ebdaaaf96ece Finland."},{"question":"Does the drive include a control unit?","answer":"Yes, the listing includes the control unit."},{"question":"What compliance documentation is available?","answer":"RoHS compliance per EU Directive 2011/65/EU (date 20240508) and REACH declaration (date 20250905) are on file. UL ratings for light-overload (1.5 Hp, 3.0 A) and heavy-duty (2.1 A) are listed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000038999","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000038999 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}