{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000039010","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000039010","canonicalUrl":"https://aoctrl.com/abb/3AXD50000039010","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000039010","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-01 wall-mounted LV AC drive, 3AXD50000039010, 7.5 kW / 17 A normal use, 380–480 V, IP55, BACnet, IE2.","salesMarkdown":"The ABB 3AXD50000039010 is an ACH580-01 wall-mounted LV AC drive built for HVAC duty. It ships with the control unit included, so you're not hunting for a separate controller board. Rated for 7.5 kW normal use at 17 A output, with a heavy-duty curve at 5.5 kW / 12.6 A for tougher fan or pump loads. Input accepts 380–480 V three-phase at 47.5–63 Hz, which covers most global mains. Enclosure is IP55 with NEMA Type 12 — fine for washdown areas or dusty mechanical rooms as long as it's not direct hose spray. Two analog inputs and two analog outputs give you room for a pressure transmitter and a speed reference pot, plus a feedback loop. Digital I/O is 6 inputs and 3 outputs — enough for start/stop, fault reset, and a run status relay. Communication is BACnet out of the box; no option card needed for BAS integration. No industrial Ethernet onboard, so if you need PROFINET or EtherNet/IP, plan for a separate gateway or a different drive variant.","metaTitle":"ABB 3AXD50000039010 ACH580-01 Drive, 7.5 kW, 17 A, IP55","metaDescription":"Active ABB ACH580-01 wall-mounted drive for HVAC. 7.5 kW normal use, 17 A output, IP55, BACnet, IE2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"f016e531-e6de-4d1f-aec7-2a367861600c Finland","Includes":"With control unit","Frame Size":"R2","Standby Loss":"15 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP55","Apparent Power Output":"12 kV·A","Communication Protocol":"BACNET","Power Consumption (@Pcons)":"240 W","Operating Humidity (RHamβ)":"95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6/3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"7.5 kW","Output Current, Normal Use (In)":"17 A","Output Power, Heavy-Duty Use (PhD)":"5.5 kW","Output Current, Heavy-Duty Use (IhD)":"12.6 A","Output Power, Light-Overload Use (PlD)":"7.5 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"16.2 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"11.0 A","Technical UL/Output Power, Light-Overload Use (UL)":"10 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"14.0 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000039010","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000039010/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for this drive?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (date 20240508). REACH declaration confirms substances above 0.1% mass (date 20250905). SCIP number f016e531-e6de-4d1f-aec7-2a367861600c Finland is on file for EU waste reporting."},{"question":"What is the closest alternative to this drive in the same family?","answer":"The ACH580-01 family offers other frame sizes and power ratings, but no pin-compatible drop-in exists at a different kW level — you'd need to re-cable for a different frame. For a functionally similar drive with the same BACnet and IP55, look at the ACH580-01 in a different current rating, but verify mounting hole pattern and gland plate dimensions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000039010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000039010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}