{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000039012","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000039012","canonicalUrl":"https://aoctrl.com/abb/3AXD50000039012","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000039012","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-01 wall-mounted HVAC drive, 3AXD50000039012, 15 kW / 32 A normal use, 380–480 V, IP55, NEMA 12, BACnet, IE2.","salesMarkdown":"The ABB 3AXD50000039012 is an ACH580-01 wall-mounted drive for HVAC applications, rated 15 kW normal use at 32 A on a 380–480 V three-phase supply. Heavy-duty use delivers 11.0 kW at 24.6 A; light-overload use reaches 15.0 kW at 30.4 A. The IP55 enclosure with NEMA Type 12 rating suits indoor installations where dust and dripping water are present. BACnet communication is built in, with 2 analog inputs and 2 analog outputs for BMS integration. Standby loss is 16 W, and the drive carries IE2 efficiency. Frame size R3, wall-mounted. Ambient temperature limited to 40 °C maximum. Operating humidity up to 95%. The enclosure is IP55 / NEMA 12, so gland plates and conduit entries must maintain the seal. Digital I/O: 6 inputs, 3 outputs. No industrial Ethernet interface; BACnet is the fieldbus. The control unit is included. A lithium coin cell (CR2032, 220 mAh) backs the real-time clock. ## UL ratings Under UL listing, heavy-duty use is rated 21.0 A; light-overload use is 20 Hp at 27.0 A. These differ from the IEC ratings (24.6 A heavy-duty, 30.4 A light-overload) and should be used for North American installations.","metaTitle":"ABB 3AXD50000039012 ACH580-01 HVAC Drive, 15 kW, 32 A, IP55","metaDescription":"Active ABB ACH580-01 wall-mounted drive, 15 kW normal use, 32 A, 380-480 V, IP55, NEMA 12, BACnet, IE2. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"7ab39eb4-9330-424a-b7ff-fcf491eb4b83 Finland","Includes":"With control unit","Frame Size":"R3","Standby Loss":"16 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP55","Apparent Power Output":"22 kV·A","Communication Protocol":"BACNET","Power Consumption (@Pcons)":"492 W","Operating Humidity (RHamβ)":"95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6/3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"15 kW","Output Current, Normal Use (In)":"32 A","Output Power, Heavy-Duty Use (PhD)":"11.0 kW","Output Current, Heavy-Duty Use (IhD)":"24.6 A","Output Power, Light-Overload Use (PlD)":"15.0 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"30.4 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"21.0 A","Technical UL/Output Power, Light-Overload Use (UL)":"20 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"27.0 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000039012","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000039012/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for this drive?","answer":"RoHS compliance dated 20240508 per EU Directive 2011/65/EU, REACH compliance dated 20250905 (contains substances > 0.1 mass percentage), and SCIP number 7ab39eb4-9330-424a-b7ff-fcf491eb4b83 Finland."},{"question":"What are the key ratings for this drive?","answer":"Normal use: 15 kW, 32 A. Heavy-duty use: 11.0 kW, 24.6 A. Light-overload use: 15.0 kW, 30.4 A. Input: 380–480 V, 3-phase, 47.5–63 Hz. Enclosure: IP55 / NEMA 12. Efficiency: IE2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000039012","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000039012 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}