{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000042304","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000042304","canonicalUrl":"https://aoctrl.com/abb/3AXD50000042304","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000042304","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580 general purpose drive, 3AXD50000042304, 11 kW normal duty, 25 A output, BACnet, IP21, R3 frame.","salesMarkdown":"## BACnet integration and I/O The 3AXD50000042304: BACnet is the onboard communication protocol, making this drive a direct fit for building automation and HVAC networks without an external gateway. The drive provides 2 analog inputs, 2 analog outputs, and 6 digital inputs / 3 digital outputs — enough for basic feedback and control loops. No Industrial Ethernet interface is present, so BACnet MS/TP over RS-485 is the expected physical layer. ## Duty ratings and headroom Three duty ratings let you match the drive to the load profile. Normal use (11 kW, 25.0 A) covers constant-torque applications like conveyors and pumps. Heavy-duty use (7.5 kW, 17.0 A) handles higher overloads — crushers, mixers, or extruders. Light-overload use (11.0 kW, 23.8 A) sits between them. The UL ratings track closely: 15 Hp / 23.0 A normal, 10 Hp / 14 A heavy-duty.","metaTitle":"ABB 3AXD50000042304 ACS580 drive, 11 kW, 25 A, BACnet, R3","metaDescription":"ABB ACS580 general purpose drive, 11 kW normal duty, 25 A output, BACnet communication, IP21, Type 1, R3 frame. Current lifecycle stage. Sourced to order via authorized channel.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"a203cde5-2de1-48cb-b0e8-df4a15913519 Finland","title":"3AXD50000042304","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R3","description":"LV AC ultra-low harmonic wall-mounted drive for HVAC, IEC: Pn 11 kW, 25.0 A, 400 V, UL: Pld 15 Hp, 23.0 A, 480 V (ACH580-31-026A-4)","Power Factor":"1.00","Sound dB (A)":"57 dB(A)","Standby Loss":"36 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The low-harmonic drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.d).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP21","Apparent Power Output":"17 kV·A","Communication Protocol":"BACNET","Power Consumption (@Pcons)":"792 W","Multiple Battery Information":"Lithium Coin; CR2032; 220 mAh; 3 V; 1 pc; 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"11 kW","Output Current, Normal Use (In)":"25.0 A","Output Power, Heavy-Duty Use (PhD)":"7.5 kW","Output Current, Heavy-Duty Use (IhD)":"17.0 A","Output Power, Light-Overload Use (PlD)":"11.0 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"23.8 A","Technical UL/Output Power, Normal Use (UL)":"15 Hp","Technical UL/Output Current, Normal Use (UL)":"23.0 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"10 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"14 A","Technical UL/Output Power, Light-Overload Use (UL)":"15 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"23.0 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9b74aebd6f4b3f48a0cf01dd1e6deed5.pdf","sourceUrl":"https://www.abb.com/global/en/products/3axd50000042304"},"ai":{"faq":[{"question":"What is the SCIP number for this drive?","answer":"The SCIP number is a203cde5-2de1-48cb-b0e8-df4a15913519 Finland."},{"question":"What is the altitude rating?","answer":"The drive is rated for installation at altitudes up to 4000 m without derating."},{"question":"What compliance documentation is available?","answer":"RoHS compliance follows EU Directive 2011/65/EU (date 20240508). REACH declaration confirms substances above 0.1% mass (date 20250905). UL ratings are provided for normal and heavy-duty use. The low-harmonic design is exempt from EU ecodesign requirements per Regulation EU/2019/1781 §2.3.d."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000042304","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000042304 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}