{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000043439","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000043439","canonicalUrl":"https://aoctrl.com/abb/3AXD50000043439","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000043439","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-04F-880A-3 LV AC industrial flange-mounted single drive module, IEC: Pn 500 kW, 880 A, 400 V, IP20, frame size R11.","salesMarkdown":"The ABB 3AXD50000043439 is an ACS880-04F-880A-3 LV AC industrial flange-mounted single drive module, rated for 500 kW normal-duty output power and 880 A continuous output current on a 400 V three-phase supply. Heavy-duty use drops to 400 kW and 725 A; light-overload use holds at 500 kW and 865 A. Input voltage range is 380–415 V, 47.5–63 Hz, three-phase. Standby losses sit at 423 W; full-load power consumption hits 10863 W. The apparent power output is 610 kV·A, which gives headroom for motor inrush and short-term overloads without tripping the line-side breaker. ## Integration notes Frame size R11, flange-mounted — plan for the physical footprint and gland-plate entry before the panel layout is locked. The module includes the control unit, so no separate controller purchase is needed. Communication is CAN-based; no onboard Ethernet, so if you need PROFINET or EtherNet/IP, budget for an optional communication adapter module. Analog I/O: 2 inputs, 2 outputs. Digital I/O: 6 inputs, 2 outputs. Sound pressure level is 75 dB(A) — not silent; ear protection is warranted if the drive is in a manned room. Operating humidity range is 5–95% RH, non-condensing. Altitude rating is 4000 m, so it handles high-altitude installations without derating up to that ceiling. The battery is a CR2032 lithium coin cell, 220 mAh, 3 V, two pieces, 6 g total — typical for parameter backup. Expect to replace it every few years if the drive is powered off for extended periods.","metaTitle":"3AXD50000043439 ABB ACS880-04F-880A-3 Drive Module, 500 kW,","metaDescription":"ABB ACS880-04F-880A-3 LV AC flange-mounted drive module, 500 kW, 880 A, 400 V, IP20, active production. RoHS/REACH compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Altitude":"4000 m","Includes":"Control unit","Frame Size":"R11","Sound dB (A)":"75 dB(A)","Standby Loss":"423 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 415 V","Degree of Protection":"IP20","Apparent Power Output":"610 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"10863 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 2 pcs, 6 g","Number of Digital In/Outputs":"6 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"500 kW","Output Current, Normal Use (In)":"880 A","Output Power, Heavy-Duty Use (PhD)":"400 kW","Output Current, Heavy-Duty Use (IhD)":"725 A","Output Power, Light-Overload Use (PlD)":"500 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250320","Output Current, Light-Overload Use (IlD)":"865 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000043439","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000043439/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this drive module carry?","answer":"RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863, dated 2024-05-08. REACH declaration confirms substances above 0.1% mass percentage, dated 2025-03-20. The spec does not list UL or IEC certification explicitly, but the module is designed to IEC standards per the description."},{"question":"What is the altitude rating for this module?","answer":"It is rated for operation up to 4000 m without derating."},{"question":"Does the module include a control unit?","answer":"Yes, the Includes field lists 'Control unit', so no separate controller purchase is required."},{"question":"What are the key output ratings for normal and heavy-duty use?","answer":"Normal-duty: 500 kW, 880 A. Heavy-duty: 400 kW, 725 A. Light-overload: 500 kW, 865 A. All at 400 V three-phase."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000043439","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000043439 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}