{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000046897","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000046897","canonicalUrl":"https://aoctrl.com/abb/3AXD50000046897","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000046897","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-11, LV AC industrial wall-mounted regenerative single drive, IEC: Pn 110 kW, 206 A, 400 V (3AXD50000046897).","salesMarkdown":"The 3AXD50000046897: The drive carries three duty curves. Normal-duty (Pn) delivers 110 kW at 206 A continuous — that is the figure for most constant-torque pump/fan applications. Heavy-duty (PhD) drops to 90 kW at 169 A, which is the rating to use for a constant-torque load like a conveyor or extruder where you need higher peak current headroom. Light-overload (PlD) also lands at 110 kW but at a slightly lower 196 A — this is for variable-torque loads where the overload profile is lighter. The apparent power output is 143 kV·A, so the drive can feed a motor with that kVA demand at unity power factor. ## Environmental limits and installation Ambient temperature maxes at +55 °C, with 5–95 % non-condensing humidity. Altitude rating goes to 4000 m — no derating needed up there, which is useful for high-altitude sites or mine installations. Sound pressure is 68 dB(A), and standby loss is 75 W, so the panel ventilation budget is modest. The drive includes a control unit, and the R8 frame is wall-mountable. Two analog inputs, two analog outputs, six digital inputs, and two digital outputs are onboard. Communication is CAN; there are no onboard Industrial Ethernet interfaces — if you need PROFINET or EtherNet/IP, you add an option module. The drive also has a lithium coin cell (CR2032, 220 mAh) for real-time clock backup — two cells, 6 g total.","metaTitle":"ABB 3AXD50000046897 Regenerative Drive, 110 kW, 206 A","metaDescription":"ABB ACS880-11 regenerative drive, 110 kW normal duty, 206 A output, 400 V input. Active production. IP21, wall-mount, R8 frame. Order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"fbdafeba-e24d-4944-bd9b-d49273a010e5 Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R8","Power Factor":"1.0","Sound dB (A)":"68 dB(A)","Standby Loss":"75 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum +55 °C","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The regenerative drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 415 V","Degree of Protection":"IP21","Apparent Power Output":"143 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"3654 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 2 pcs, 6 g","Number of Digital In/Outputs":"6 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"110 kW","Output Current, Normal Use (In)":"206 A","Output Power, Heavy-Duty Use (PhD)":"90 kW","Output Current, Heavy-Duty Use (IhD)":"169 A","Output Power, Light-Overload Use (PlD)":"110 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"196 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000046897","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000046897/alternatives.json"},"ai":{"faq":[{"question":"What are the key output ratings for this drive?","answer":"Normal-duty output is 110 kW at 206 A; heavy-duty is 90 kW at 169 A; light-overload is 110 kW at 196 A. Input is 380–415 V three-phase, 47.5–63 Hz."},{"question":"What compliance documentation is available for this drive?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (declaration date 20240508). REACH registered (date 20250905). SCIP number fbdafeba-e24d-4944-bd9b-d49273a010e5 Finland. WEEE category 4. The regenerative drive is exempt from EU ecodesign energy efficiency reporting."},{"question":"What is the SCIP number for this product?","answer":"The SCIP number is fbdafeba-e24d-4944-bd9b-d49273a010e5 Finland."},{"question":"What is the altitude rating of this drive?","answer":"The drive is rated for altitudes up to 4000 m without derating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000046897","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000046897 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}