{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000047395","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000047395","canonicalUrl":"https://aoctrl.com/abb/3AXD50000047395","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000047395","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880, R8 frame, 55 kW normal-duty drive, 101 A output, 380–500 V three-phase, IP21, wall-mounted.","salesMarkdown":"The ABB 3AXD50000047395 is an ACS880-series drive in an R8 frame, delivering 55 kW output at 101 A under normal duty (Light-Overload Use rated 55 kW at 91 A). For heavy-duty applications it's rated 45 kW at 77 A, with a UL heavy-duty output of 60 Hp at 77 A. Input is three-phase 380–500 V, 47.5–63 Hz. Enclosure is IP21 with NEMA Type 1, wall-mounted. Ambient temperature max is +55 °C. Efficiency class is IE2. The drive includes a control unit and draws 1577 W at rated load, with 89 W standby loss. Ecodesign exemption applies — regenerative drives are exempt from EU energy efficiency data requirements per Regulation EU/2019/1781 §2.3.c. Altitude rating is 4000 m. Sound level 68 dB(A). ## I/O and integration Onboard I/O includes 2 analog inputs, 2 analog outputs, 6 digital inputs, and 2 digital outputs. Communication protocol is CAN; no onboard Industrial Ethernet (0 hardware interfaces). The drive includes a lithium coin cell (CR2032, 220 mAh, 3 V, 2 pcs) for real-time clock backup.","metaTitle":"ABB 3AXD50000047395 ACS880 Drive, R8 Frame, 55 kW, 101 A","metaDescription":"ABB 3AXD50000047395 ACS880 drive, R8 frame, 55 kW normal duty, 101 A output. Active production. 380-500 V, IP21. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"SCIP":"a8974b22-8596-4130-8a8f-51671d307fb7 Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R8","Power Factor":"1.0","Sound dB (A)":"68 dB(A)","Standby Loss":"89 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum +55 °C","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The regenerative drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP21","Apparent Power Output":"87 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"1577 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 2 pcs, 6 g","Number of Digital In/Outputs":"6 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"55 kW","Output Current, Normal Use (In)":"101 A","Output Power, Heavy-Duty Use (PhD)":"45.0 kW","Output Current, Heavy-Duty Use (IhD)":"77 A","Output Power, Light-Overload Use (PlD)":"55.0 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"91 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"60.0 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"77.0 A","Technical UL/Output Power, Light-Overload Use (UL)":"75 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"96 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000047395","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000047395/alternatives.json"},"ai":{"faq":[{"question":"What are the key power ratings for this drive?","answer":"Normal duty: 55 kW at 101 A. Heavy duty: 45 kW at 77 A (UL: 60 Hp at 77 A). Light-overload use: 55 kW at 91 A. Input is 380–500 V three-phase."},{"question":"What compliance documentation is available?","answer":"RoHS compliant per EU 2011/65/EU (declaration date 20240508). REACH declaration date 20250905. SCIP number a8974b22-8596-4130-8a8f-51671d307fb7. UL ratings provided for heavy-duty and light-overload use. Ecodesign exemption applies per EU/2019/1781 §2.3.c."},{"question":"What is the enclosure protection and mounting?","answer":"IP21, NEMA Type 1, wall-mounted. Ambient temperature max +55 °C, altitude rating 4000 m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000047395","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000047395 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}