{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000049020","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000049020","canonicalUrl":"https://aoctrl.com/abb/3AXD50000049020","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000049020","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-07 cabinet-built drive, 3AXD50000049020, 90 kW / 169 A normal duty, 380-480 V, IP21, BACnet, frame R7.","salesMarkdown":"The ABB 3AXD50000049020 is an ACH580-07 LV AC cabinet-built drive for HVAC, rated 90 kW normal-use output at 169 A on a 400 V supply, with heavy-duty capability at 75 kW and 145 A. It runs on three-phase 380–480 V input and is built into an IP21, NEMA Type 1 enclosure — ready for indoor panel installation without an extra cabinet. Frame size R7 and a cabinet-built mounting mean this drive arrives as a self-contained unit — no separate enclosure to spec. The 169 A normal-use current (161 A light-overload) drives a 90 kW motor; heavy-duty profile drops to 145 A at 75 kW for constant-torque loads like conveyors or positive-displacement pumps. UL ratings mirror the IEC: 125 Hp light-overload at 156 A, 100 Hp heavy-duty at 124 A. BACnet is on board as the native protocol — no option card needed for BAS integration. Two analog inputs and two analog outputs cover standard sensor feedback and speed reference; six digital inputs and three digital outputs handle start/stop, fault reset, and status. Frequency range is 47.5–63 Hz, covering 50 and 60 Hz mains. Rated for ambient temperatures up to 40 °C and humidity from 5 to 95% — fine for most mechanical rooms. Sound level is 67 dB(A) at full load; factor that into nearby occupancy. Power consumption at rated load is 2497 W, mostly dissipated as heat in the cabinet. Lifecycle status is active — this is a current-production part, not a phase-out or last-time-buy. ## Sourcing and documentation The drive includes the control unit; the only user-serviceable battery is a CR2032 lithium coin cell (3 V, 220 mAh) for the real-time clock. WEEE category 4 (large equipment) applies for end-of-life handling. This is a quoted-to-order item; submit an RFQ for lead time and pricing.","metaTitle":"ABB 3AXD50000049020 ACH580-07 Drive, 90 kW, 169 A, IP21","metaDescription":"ABB 3AXD50000049020 ACH580-07 cabinet-built HVAC drive, 90 kW normal duty, 169 A, 380-480 V, IP21, BACnet, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"f8697513-3243-4f24-9777-7dbe1d791662 Finland","title":"3AXD50000049020","Includes":"Control unit","Frame Size":"R7","description":"LV AC cabinet-built drive for HVAC, IEC: Pn 90 kW, 169 A, 400 V, UL: Pld 125 Hp, 156 A, 480 V (ACH580-07-0169A-4)","Sound dB (A)":"67 dB(A)","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Cabinet-built","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Ecodesign Exemption":"Energy efficiency data is not provided for this cabinet-based drive. Cabinet built drives, with already conform modules, are excluded from the scope of the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.e).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP21","Apparent Power Output":"117 kV·A","Communication Protocol":"BACNET","Power Consumption (@Pcons)":"2497 W","Operating Humidity (RHamβ)":"5 to 95%","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"90 kW","Output Current, Normal Use (In)":"169 A","Output Power, Heavy-Duty Use (PhD)":"75 kW","Output Current, Heavy-Duty Use (IhD)":"145 A","Output Power, Light-Overload Use (PlD)":"90 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"161 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"100 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"124 A","Technical UL/Output Power, Light-Overload Use (UL)":"125 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"156 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9c94afce07d86528b32a6bbd4cabb094.pdf","sourceUrl":"https://www.abb.com/global/en/products/3axd50000049020"},"ai":{"faq":[{"question":"What are the key ratings for this drive?","answer":"Normal-use output is 90 kW at 169 A; heavy-duty is 75 kW at 145 A. Input is 380–480 V three-phase. IP21, NEMA Type 1 enclosure. BACnet communication is built in."},{"question":"What compliance documentation does this drive have?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (date 20240508). REACH declaration date 20250905 with substances >0.1% mass. SCIP number f8697513-3243-4f24-9777-7dbe1d791662 Finland. UL ratings for heavy-duty (100 Hp, 124 A) and light-overload (125 Hp, 156 A) are listed."},{"question":"What is included with this drive?","answer":"It includes the control unit. A CR2032 lithium coin cell (3 V, 220 mAh) is fitted for the real-time clock."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000049020","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000049020 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}