{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000049035","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000049035","canonicalUrl":"https://aoctrl.com/abb/3AXD50000049035","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000049035","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-07 series, LV AC cabinet-built drive for HVAC, 3AXD50000049035, 250 kW normal use, 430 A, 380-480 V, IP21, NEMA 1, BACnet.","salesMarkdown":"It's rated for 250 kW normal use at 430 A on a 380...480 V three-phase supply, with heavy-duty use at 200 kW / 363 A and light-overload at 200 kW / 400 A. UL ratings are 300 Hp heavy-duty / 361 A and 350 Hp light-overload / 414 A. Enclosure is IP21, NEMA Type 1, frame size R9, and it includes the control unit. Communication is BACnet; no industrial Ethernet interface on this variant. Heavy-duty at 363 A covers constant-torque applications like conveyors or compressors. The 35 °C maximum ambient temperature is the design point — if your mechanical room runs hotter, you'll need to derate or add ventilation. Apparent power output of 298 kVA gives you the transformer sizing number for the incoming feed. Power consumption of 7600 W is the drive's own losses at full load, so factor that into your panel cooling. Cabinet-built, frame R9, IP21 with NEMA 1. That means it's intended for indoor installation with some protection from dripping water. Sound level is 68 dB(A) — noticeable in a quiet room but typical for this power class. Operating humidity 5 to 95% non-condensing. Frequency range 47.5...63 Hz covers 50 and 60 Hz grids. The lithium coin cell (CR2032, 220 mAh) backs up the real-time clock; it's field-replaceable. ## I/O & Communication Two analog inputs and two analog outputs are standard for feedback and setpoint signals. Six digital inputs and three digital outputs handle start/stop, fault reset, and status. BACnet is the only fieldbus on this order code — no Ethernet port. If you need Modbus TCP or PROFINET, that's a different variant. The control unit is included, so no separate ordering for the basic brain.","metaTitle":"ABB 3AXD50000049035 ACH580-07 Cabinet Drive, 250 kW, 430 A","metaDescription":"ABB 3AXD50000049035 ACH580-07 LV AC cabinet-built drive for HVAC. Rated 250 kW normal use, 430 A, 380-480 V, IP21, NEMA 1. Active production, BACnet. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"105dd15e-a9d4-40aa-a399-53b46cd95cf3 Finland","title":"3AXD50000049035","Includes":"Control unit","Frame Size":"R9","description":"LV AC cabinet-built drive for HVAC, IEC: Pn 250 kW, 430 A, 400 V, UL: Pld 350 Hp, 414 A, 480 V (ACH580-07-0430A-4)","Sound dB (A)":"68 dB(A)","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Cabinet-built","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Number of Phases":"3-phase","Temperature Rating":"Maximum 35 °C","Ecodesign Exemption":"Energy efficiency data is not provided for this cabinet-based drive. Cabinet built drives, with already conform modules, are excluded from the scope of the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.e).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP21","Apparent Power Output":"298 kV·A","Communication Protocol":"BACNET","Power Consumption (@Pcons)":"7600 W","Operating Humidity (RHamβ)":"5 to 95%","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"250 kW","Output Current, Normal Use (In)":"430 A","Output Power, Heavy-Duty Use (PhD)":"200 kW","Output Current, Heavy-Duty Use (IhD)":"363 A","Output Power, Light-Overload Use (PlD)":"200 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"400 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"300 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"361 A","Technical UL/Output Power, Light-Overload Use (UL)":"350 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"414 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6bb49657096b880efcbe5892a79ac39a.pdf","sourceUrl":"https://www.abb.com/global/en/products/3axd50000049035"},"ai":{"faq":[{"question":"What compliance documentation is available for this drive?","answer":"RoHS compliance dated 20240508, REACH declaration dated 20250905, SCIP number 105dd15e-a9d4-40aa-a399-53b46cd95cf3 Finland, and an ecodesign exemption for cabinet-built drives. UL ratings are provided for heavy-duty and light-overload use."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000049035","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000049035 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}