{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000049039","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000049039","canonicalUrl":"https://aoctrl.com/abb/3AXD50000049039","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000049039","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-07 cabinet-built drive, R8 frame, 380-480 V, 132 kW / 246 A normal use, 110 kW / 206 A heavy-duty, IP21, current lifecycle.","salesMarkdown":"It delivers 132 kW normal-use output (246 A) and 110 kW heavy-duty output (206 A) on a 380-480 V three-phase supply, IP21 enclosure, with a control unit included. ## Duty ratings that matter Three duty ratings are on the nameplate: normal use (Pn 132 kW, In 246 A), heavy-duty (PhD 110 kW, IhD 206 A), and light-overload (PlD 132 kW, IlD 234 A). ## Integration notes Cabinet-built means it arrives as a complete assembly — mount it, land the incoming 3-phase 380-480 V, and connect the motor. The R8 frame is sized for the 246 A output; plan gland-plate space accordingly. Ambient max is 40 °C, humidity 5-95% non-condensing. Sound level is 65 dB(A). The control unit includes 2 analog inputs, 2 analog outputs, 6 digital inputs, 3 digital outputs, and CAN communication — no onboard industrial Ethernet (0 interfaces). A CR2032 lithium coin cell backs the real-time clock.","metaTitle":"ABB 3AXD50000049039 ACQ580-07 Cabinet Drive, 132 kW, 246 A","metaDescription":"ABB ACQ580-07 cabinet-built drive, 132 kW normal use (246 A), 110 kW heavy-duty (206 A), 380-480 V, IP21, R8 frame, current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"182c528b-29d6-4b33-89d3-2ec8b482ca1d Finland","Includes":"Control unit","Frame Size":"R8","Power Factor":"0.98","Sound dB (A)":"65 dB(A)","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Cabinet-built","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Ecodesign Exemption":"Energy efficiency data is not provided for this cabinet-based drive. Cabinet built drives, with already conform modules, are excluded from the scope of the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.e).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP21","Apparent Power Output":"170 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"3806 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"132 kW","Output Current, Normal Use (In)":"246 A","Output Power, Heavy-Duty Use (PhD)":"110 kW","Output Current, Heavy-Duty Use (IhD)":"206 A","Output Power, Light-Overload Use (PlD)":"132 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"234 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"150 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"180 A","Technical UL/Output Power, Light-Overload Use (UL)":"200 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"240 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000049039","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000049039/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available?","answer":"RoHS compliance per EU Directive 2011/65/EU (date 20240508), REACH compliance (date 20250905) with a substance declaration above 0.1% mass, and SCIP number 182c528b-29d6-4b33-89d3-2ec8b482ca1d Finland. The drive is UL-listed for heavy-duty (150 Hp, 180 A) and light-overload (200 Hp, 240 A) use."},{"question":"What does the control unit include?","answer":"The drive includes a control unit with 2 analog inputs, 2 analog outputs, 6 digital inputs, 3 digital outputs, and CAN communication. No onboard industrial Ethernet interfaces."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000049039","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000049039 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}