{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000050471","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000050471","canonicalUrl":"https://aoctrl.com/abb/3AXD50000050471","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000050471","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-07 series, LV AC cabinet-built drive, 3AXD50000050471, 315 kW / 585 A normal use, 380–480 V, IP21, BACnet.","salesMarkdown":"The ABB 3AXD50000050471 is an ACH580-07 cabinet-built drive rated 315 kW normal-use output (585 A) at 400 V, with a heavy-duty rating of 250 kW (429 A) and light-overload output of 315 kW (575 A). Input is 380–480 V three-phase, 47.5–63 Hz. The IP21 enclosure (NEMA Type 1) suits indoor HVAC or industrial installations where drip protection is sufficient. Built-in BACnet communication protocol for building automation integration. Two analog inputs and two analog outputs are available for process signals; six digital inputs and three digital outputs handle discrete control. No onboard industrial Ethernet interface — BACnet MS/TP or other serial protocols are the primary fieldbus.","metaTitle":"ABB 3AXD50000050471 ACH580-07 Drive, 315 kW, 585 A, 400 V","metaDescription":"ABB 3AXD50000050471 ACH580-07 cabinet-built drive. 315 kW / 585 A normal use, 380–480 V, IP21, BACnet, active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"e531a9e8-f7f6-4242-8b63-c885daa80d86 Finland","title":"3AXD50000050471","Includes":"Control unit","Frame Size":"R10","description":"LV AC cabinet-built drive for HVAC, IEC: Pn 315 kW, 585 A, 400 V, UL: Pld 450 Hp, 573 A, 480 V (ACH580-07-0585A-4)","Sound dB (A)":"72 dB(A)","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Cabinet-built","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Ecodesign Exemption":"Energy efficiency data is not provided for this cabinet-based drive. Cabinet built drives, with already conform modules, are excluded from the scope of the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.e).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP21","Apparent Power Output":"405 kV·A","Communication Protocol":"BACNET","Power Consumption (@Pcons)":"9471 W","Operating Humidity (RHamβ)":"5 to 95%","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"315 kW","Output Current, Normal Use (In)":"585 A","Output Power, Heavy-Duty Use (PhD)":"250 kW","Output Current, Heavy-Duty Use (IhD)":"429 A","Output Power, Light-Overload Use (PlD)":"315 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"575 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"350 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"414 A","Technical UL/Output Power, Light-Overload Use (UL)":"450 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"573 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1ec675b270598a319687b878707e8326.pdf","sourceUrl":"https://www.abb.com/global/en/products/3axd50000050471"},"ai":{"faq":[{"question":"What compliance documentation does ABB provide for this drive?","answer":"RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863, REACH declaration (contains substances >0.1% mass), and UL listing with heavy-duty output of 350 Hp / 414 A and light-overload output of 450 Hp / 573 A at 480 V."},{"question":"What is the SCIP number for 3AXD50000050471?","answer":"SCIP number e531a9e8-f7f6-4242-8b63-c885daa80d86, registered in Finland."},{"question":"Does this drive include a control unit?","answer":"Yes, the listing includes a control unit as part of the drive package."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000050471","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000050471 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}