{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000050476","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000050476","canonicalUrl":"https://aoctrl.com/abb/3AXD50000050476","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000050476","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-07-0505A-4, LV AC cabinet-built drive for water and wastewater, IEC: Pn 250 kW, 505 A, 400 V, UL: Pld 400 Hp, 483 A, 480 V.","salesMarkdown":"The ABB 3AXD50000050476 is an ACQ580-07-0505A-4 LV AC cabinet-built drive, purpose-configured for water and wastewater applications. It ships with the control unit included, so you are not sourcing a separate controller board for the cabinet build. Frame size R10, IP21 with NEMA Type 1 enclosure — rated for indoor installation where drips and falling dirt are the concern, not hose-down. Input accepts 380 to 480 V three-phase, 47.5 to 63 Hz. On the output side, normal-use rating is 250 kW at 505 A; heavy-duty use (constant torque) drops to 200 kW at 361 A. Light-overload use holds at 250 kW but pulls 485 A. UL ratings mirror the heavy-duty and light-overload currents at 361 A and 483 A respectively, with horsepower figures of 300 Hp and 400 Hp at 480 V. That 0.98 power factor keeps the upstream transformer and cabling sized closer to the real kW than the kVA. The 505 A normal-use output current is the number to match against your motor FLA. If your load profile is variable torque (pumps, fans), the normal-use rating applies. The 72 dB(A) sound level is worth noting for noise-sensitive installations; it is not silent, but it is typical for a 250 kW cabinet drive in this frame class. Analog I/O is 2 inputs and 2 outputs, digital I/O is 6 inputs and 3 outputs. Communication is CAN — no onboard Industrial Ethernet, so if you need PROFINET or EtherNet/IP, plan for an optional fieldbus adapter module. The 8353 W power consumption at rated load is the heat to reject from the cabinet; factor that into your ventilation or air-conditioning budget. Operating humidity range is 5 to 95% RH, non-condensing. Maximum ambient temperature is 40 °C. The lithium coin cell (CR2032, 220 mAh, 3 V) backs up the real-time clock and parameter storage.","metaTitle":"3AXD50000050476 ABB ACQ580-07-0505A-4 LV AC Drive, 250 kW, 5","metaDescription":"ABB ACQ580-07 cabinet-built drive for water/wastewater. 250 kW normal use, 505 A output, IP21, Type 1. Current production. RoHS/REACH compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"e531a9e8-f7f6-4242-8b63-c885daa80d86 Finland","Includes":"Control unit","Frame Size":"R10","Power Factor":"0.98","Sound dB (A)":"72 dB(A)","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Cabinet-built","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Ecodesign Exemption":"Energy efficiency data is not provided for this cabinet-based drive. Cabinet built drives, with already conform modules, are excluded from the scope of the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.e).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP21","Apparent Power Output":"350 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"8353 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 1 pc, 3 g","Number of Digital In/Outputs":"6 / 3","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"250 kW","Output Current, Normal Use (In)":"505 A","Output Power, Heavy-Duty Use (PhD)":"200 kW","Output Current, Heavy-Duty Use (IhD)":"361 A","Output Power, Light-Overload Use (PlD)":"250 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"485 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"300 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"361 A","Technical UL/Output Power, Light-Overload Use (UL)":"400 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"483 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000050476","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000050476/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this drive have?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (declaration date 20240508). REACH declaration confirms substances above 0.1 mass percentage (date 20250905). SCIP number is e531a9e8-f7f6-4242-8b63-c885daa80d86 Finland. Ecodesign exemption applies per EU 2019/1781 §2.3.e for cabinet-built drives."},{"question":"Does the drive include a control unit?","answer":"Yes, the listing specifies 'Includes Control unit' — the drive ships with the control electronics, so no separate controller module purchase is needed for the cabinet build."},{"question":"What is the SCIP number for this drive?","answer":"The SCIP number is e531a9e8-f7f6-4242-8b63-c885daa80d86 Finland, required for EU waste reporting under the SCIP database."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000050476","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000050476 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}