{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000110384","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000110384","canonicalUrl":"https://aoctrl.com/abb/3AXD50000110384","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000110384","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580 general-purpose drive, 3AXD50000110384, 3 kW normal-duty, 12.2 A output, R2 frame, IP20, 200-240 VAC 3-phase.","salesMarkdown":"The 3AXD50000110384: Input voltage is 200–240 VAC three-phase at 47.5–63 Hz, so it fits standard North American and global low-voltage grids. The IP20 open-type enclosure means it belongs in a cabinet — no washdown environments. Maximum ambient 50 °C, altitude 1000 m without derating; above that you'll need to reduce output current per the drive manual. ## Built-in I/O and fieldbus — what you get on the terminal block Two digital inputs and one digital output are onboard — enough for a basic start/stop and a fault relay, but not for multi-sensor feedback. No analog I/O, so any process setpoint must come via the CAN fieldbus. The drive speaks CAN as standard; if your network is PROFINET or EtherNet/IP, you'll need an optional fieldbus adapter module that slots into the drive's expansion bay.","metaTitle":"3AXD50000110384 ABB ACS580 drive, 3 kW, 12.2 A, R2 frame","metaDescription":"ABB ACS580 drive, 3AXD50000110384, 3 kW normal-duty, 12.2 A output, R2 frame. RoHS/REACH/UL compliant. Sourced to order. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"171cbe90-f958-4bba-b9dd-e62c0f6b4011 Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R2","Power Factor":"0.98","Sound dB (A)":"58.80 dB(A)","Standby Loss":"15 W","Analog Inputs":"0","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"0","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP20","Apparent Power Output":"4.9 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"149 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"2 / 1","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"3 kW","Output Current, Normal Use (In)":"12.2 A","Output Power, Heavy-Duty Use (PhD)":"2.2 kW","Output Current, Heavy-Duty Use (IhD)":"9.8 A","Output Power, Light-Overload Use (PlD)":"3.0 kW","Certificates and Declarations/RoHS Date":"20230303","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"11.6 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"3 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"9.3 A","Technical UL/Output Power, Light-Overload Use (UL)":"3 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"11.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000110384","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000110384/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive?","answer":"The SCIP number is 171cbe90-f958-4bba-b9dd-e62c0f6b4011 Finland."},{"question":"What compliance documentation is available?","answer":"RoHS (2011/65/EU, date 20230303) and REACH (date 20250905) declarations are on file. UL listing covers heavy-duty and light-overload ratings. WEEE category 5 applies."},{"question":"What are the key output ratings?","answer":"Normal-duty (light-overload): 3 kW, 11.6 A. Heavy-duty: 2.2 kW, 9.8 A. UL heavy-duty: 3 HP, 9.3 A."},{"question":"What communication protocol does it support?","answer":"Standard CAN fieldbus. No onboard Ethernet; an optional adapter is required for PROFINET or EtherNet/IP."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000110384","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000110384 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}