{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000120970","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000120970","canonicalUrl":"https://aoctrl.com/abb/3AXD50000120970","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000120970","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-31 LV AC industrial wall-mounted low harmonic single drive, IEC: Pn 11 kW, 25 A, 400 V, frame R3, IP21.","salesMarkdown":"The 3AXD50000120970: Normal-use (Pn 11 kW, In 25 A) covers constant-torque applications. Heavy-duty use (PhD 7.5 kW, IhD 17 A) applies for higher overload cycles. Light-overload use (PlD 11 kW, IlD 24 A) is the same power as normal but with slightly lower continuous current. Rated for ambient up to +55 °C and 5–95 % RH non-condensing. Altitude ceiling 4000 m without derating, which covers most installations outside high-mountain sites. Sound level 57 dB(A) at full load — noticeable in a quiet room but unremarkable on a production floor. Standby loss 39 W; factor that into enclosure cooling if the drive sits idle for long periods. Two analog inputs, two analog outputs, six digital inputs, two digital outputs — enough for basic speed reference, feedback, and run/stop control without an expansion module. CAN protocol on board for drive-to-drive or PLC communication over a CANopen network. No onboard Industrial Ethernet port, so if you need PROFINET or EtherNet/IP, plan for an optional fieldbus adapter. The control unit is included in the delivery. ## Power consumption and efficiency At rated output the drive draws 822 W from the line (Pcons). Apparent power output is 17 kV·A. Power factor is unity (1.0) — the active front end of the low-harmonic design keeps PF near 1 across the load range, which saves on upstream transformer and cable sizing compared to a 6-pulse drive with a DC choke.","metaTitle":"ABB 3AXD50000120970 ACS880-31 Drive, 11 kW, 25 A, IP21","metaDescription":"ABB ACS880-31 low-harmonic drive, 11 kW normal-use, 25 A output, IP21, R3 frame. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"a0a1d113-f955-442a-b6de-30f51c3ebadb Finland","Altitude":"4000 m","Includes":"Control unit","Frame Size":"R3","Power Factor":"1.0","Sound dB (A)":"57 dB(A)","Standby Loss":"39 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum +55 °C","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The low-harmonic drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.d).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 415 V","Degree of Protection":"IP21","Apparent Power Output":"17 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"822 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 220 mAh, 3 V, 2 pcs, 6 g","Number of Digital In/Outputs":"6 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"11 kW","Output Current, Normal Use (In)":"25 A","Output Power, Heavy-Duty Use (PhD)":"7.5 kW","Output Current, Heavy-Duty Use (IhD)":"17 A","Output Power, Light-Overload Use (PlD)":"11 kW","Certificates and Declarations/RoHS Date":"20240508","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"24 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000120970","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000120970/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive?","answer":"The SCIP substance identifier is a0a1d113-f955-442a-b6de-30f51c3ebadb Finland."},{"question":"What is the maximum altitude for installation without derating?","answer":"The drive is rated for installation at altitudes up to 4000 m."},{"question":"What compliance documentation is available?","answer":"RoHS compliance per EU Directive 2011/65/EU and REACH registration are documented. The SCIP number is on file. The drive is exempt from EU ecodesign efficiency requirements under Regulation EU/2019/1781 §2.3.d."},{"question":"What is the normal-use output current rating?","answer":"Normal-use output current is 25 A at 11 kW. Heavy-duty rating is 17 A at 7.5 kW."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000120970","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000120970 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}