{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000145942","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000145942","canonicalUrl":"https://aoctrl.com/abb/3AXD50000145942","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000145942","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-17-1450A-7 regenerative drive, 1400 kW normal-use output, 1450 A output current, 525...690 V three-phase input, IP22, NEMA Type 1.","salesMarkdown":"The ABB 3AXD50000145942 is an ACS880-17-1450A-7 regenerative drive rated for 1400 kW normal-use output and 1450 A continuous current. It runs on a 525...690 V three-phase supply at 48...63 Hz and comes in a 3xR8i+3xR8i frame size with a NEMA Type 1 enclosure and IP22 protection. This is a regenerative drive, meaning it can return braking energy to the line instead of burning it as heat in a resistor. That makes it exempt from the EU ecodesign efficiency requirements (Regulation EU/2019/1781, §2.3.c) — the standard efficiency tables don't apply here. Light-overload use (e.g., pumps, fans) sits at 1392 A (1300 kW). UL listings mirror these: 1500 HP normal, 1100 HP heavy-duty, 1500 HP light-overload. Apparent power output is 1733 kVA, which gives you the transformer sizing ballpark. Ambient temperature is capped at 40 °C, and altitude is rated to 1000 m without derating — above that you'll need to reduce current or add cooling. ## I/O and communications The drive includes 4 analog inputs, 4 analog outputs, 14 digital inputs, and 10 digital outputs. Communication is CAN-based; there are no onboard industrial Ethernet ports (0 hardware interfaces for that). If you need Ethernet/IP, PROFINET, or Modbus TCP, you'll add an option module. ## Physical and environmental Sound level is 78 dB(A) — expect fan noise in a drive this size. Operating humidity range is 5...95% non-condensing. The control unit is included, and the drive ships with two BR2032 lithium coin cells (3 V, 200 mAh each) for backup.","metaTitle":"ABB 3AXD50000145942 ACS880-17 Drive, 1400 kW, 1450 A","metaDescription":"ABB ACS880-17-1450A-7 regenerative drive, 1400 kW normal use, 1450 A output, 525-690 V input, IP22, NEMA 1. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"SCIP":"944D8A5E-036D-404E-9036-0D3C1EA703AD Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"3xR8i+3xR8i","Power Factor":"1","Sound dB (A)":"78 dB(A)","Analog Inputs":"4","Frequency (f)":"48 ... 63 Hz","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"4","lifecycle_stage":"current","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The regenerative drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"525 ... 690 V","Degree of Protection":"IP22","Apparent Power Output":"1733 kV·A","Communication Protocol":"CAN","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, BR2032, 2pcs, 3V, 200mAh, 3g","Number of Digital In/Outputs":"14 / 10","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"1400 kW","Output Current, Normal Use (In)":"1450 A","Output Power, Heavy-Duty Use (PhD)":"1000 kW","Output Current, Heavy-Duty Use (IhD)":"1085 A","Output Power, Light-Overload Use (PlD)":"1300 kW","Output Current, Light-Overload Use (IlD)":"1392 A","Technical UL/Output Power, Normal Use (UL)":"1500 Hp","Technical UL/Output Current, Normal Use (UL)":"1450 A","Technical UL/Output Power, Heavy-Duty Use (UL)":"1100 Hp","Technical UL/Output Current, Heavy-Duty Use (UL)":"1085 A","Technical UL/Output Power, Light-Overload Use (UL)":"1500 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"1392 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000145942","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000145942/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this drive?","answer":"Normal-use output is 1400 kW / 1450 A; heavy-duty is 1000 kW / 1085 A; light-overload is 1300 kW / 1392 A. Input voltage is 525...690 V three-phase at 48...63 Hz. Apparent power is 1733 kVA."},{"question":"What enclosure and protection rating does it have?","answer":"NEMA Type 1 enclosure with IP22 degree of protection. It's suitable for indoor, dry locations."},{"question":"Does this drive have industrial Ethernet onboard?","answer":"No. It has 0 industrial Ethernet hardware interfaces. Communication is CAN-based; Ethernet option modules are available separately."},{"question":"What is the SCIP number for this drive?","answer":"SCIP: 944D8A5E-036D-404E-9036-0D3C1EA703AD Finland."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000145942","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000145942 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}