{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000145997","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000145997","canonicalUrl":"https://aoctrl.com/abb/3AXD50000145997","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000145997","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-17, 3AXD50000145997, regenerative drive, 3200 kW normal-use output, 3310 A normal-use current, 525-690 V input, IP22 enclosure.","salesMarkdown":"## Duty ratings that matter for your application The 3AXD50000145997: Normal-use output (PN) is 3200 kW at 3310 A; for heavy-duty cycles the drive delivers 2400 kW at 2476 A (IhD), and for light-overload use it provides 3000 kW at 3178 A (IlD). The apparent power rating is 3956 kVA. These figures let you match the drive to the load profile — heavy-duty for constant-torque or high-starting-torque applications, light-overload for variable-torque loads like pumps and fans. ## Enclosure, protection, and mounting The drive is housed in a NEMA Type 1 enclosure with IP22 protection, suitable for indoor installation where falling dirt and dripping water are the main concerns. Frame size is 6xR8i+6xR8i — a large multi-cabinet configuration that requires floor space and proper ventilation. The unit includes four analog inputs and four analog outputs, plus 14 digital inputs and 10 digital outputs for control and feedback wiring. ## Compliance and environmental notes The drive is exempt from EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c) because it is a regenerative drive — energy efficiency data is not provided. SCIP number is 944D8A5E-036D-404E-9036-0D3C1EA703AD Finland. The unit contains two lithium coin cells (BR2032, 3V, 200 mAh each) for backup. Operating humidity range is 5-95% RH. The WEEE category is 4 (Large Equipment, any external dimension more than 50 cm).","metaTitle":"ABB 3AXD50000145997 ACS880-17 Drive, 3200 kW, 3310 A","metaDescription":"Active-production ABB ACS880-17 regenerative drive, 3200 kW normal use, 3310 A output, 525-690 V input, IP22, NEMA 1. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"SCIP":"944D8A5E-036D-404E-9036-0D3C1EA703AD Finland","Includes":"Control unit","Frame Size":"6xR8i+6xR8i","Power Factor":"1","Analog Inputs":"4","Frequency (f)":"48 ... 63 Hz","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"4","lifecycle_stage":"current","Number of Phases":"3-phase","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The regenerative drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"525 ... 690 V","Degree of Protection":"IP22","Apparent Power Output":"3956 kV·A","Communication Protocol":"CAN","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, BR2032, 2pcs, 3V, 200mAh, 3g","Number of Digital In/Outputs":"14 / 10","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"3200 kW","Output Current, Normal Use (In)":"3310 A","Output Power, Heavy-Duty Use (PhD)":"2400 kW","Output Current, Heavy-Duty Use (IhD)":"2476 A","Output Power, Light-Overload Use (PlD)":"3000 kW","Output Current, Light-Overload Use (IlD)":"3178 A","Technical UL/Output Current, Normal Use (UL)":"3310 A","Technical UL/Output Power, Heavy-Duty Use (UL)":"2700 Hp","Technical UL/Output Current, Heavy-Duty Use (UL)":"2476 A","Technical UL/Output Current, Light-Overload Use (UL)":"3178 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000145997","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000145997/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the 3AXD50000145997?","answer":"Normal-use output is 3200 kW at 3310 A; heavy-duty output is 2400 kW at 2476 A; light-overload output is 3000 kW at 3178 A. Input voltage is 525-690 V three-phase at 48-63 Hz."},{"question":"What is the SCIP number for this drive?","answer":"The SCIP number is 944D8A5E-036D-404E-9036-0D3C1EA703AD Finland."},{"question":"Does the drive include a control unit?","answer":"Yes, the control unit is included with the drive."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000145997","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000145997 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}