{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000146024","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000146024","canonicalUrl":"https://aoctrl.com/abb/3AXD50000146024","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000146024","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-37 series, 3AXD50000146024, 250 kW normal-use output, 442 A normal-use current, frame size R11, IP22, NEMA Type 1.","salesMarkdown":"The 3AXD50000146024: Normal-use (Pn 250 kW, In 442 A) is the headline number for continuous motor loads — pumps, fans, conveyors running at nameplate. Heavy-duty (PhD 200 kW, IhD 363 A) is the one you size against for constant-torque loads like extruders or crushers that need full torque at low speed. Light-overload (PlD 250 kW, IlD 420 A) sits between them; the 442 A normal-use figure is the one that fills the BOM line for most applications. The 306 kV·A apparent power output tells you the transformer and cable sizing upstream. Status is active — no LTB window, no NRND flag. This is a current-production variant, so you can quote it into a BOM without a last-time-buy clock. Sourced to order again. ## What fits in the panel Frame R11 is the physical envelope — expect a cabinet-mounted drive, not a wall-mount puck. IP22 means protected against finger contact and dripping water; keep it indoors or in a NEMA 1 enclosure (which it already carries). Ambient max 40 °C, altitude 1000 m without derating. The 77 dB(A) sound level is noticeable in a quiet control room — plan for separation or ear protection if it runs near operators. Two analog inputs and two analog outputs are on board; 7 digital inputs and 5 digital outputs cover basic I/O without an expansion module. CAN is the onboard fieldbus; no Industrial Ethernet port on this variant, so if the line needs PROFINET or EtherNet/IP, you'll add an option module.","metaTitle":"ABB 3AXD50000146024 ACS880-37 Drive, 250 kW, 442 A","metaDescription":"ABB ACS880-37-0442A-3 drive, 250 kW normal-use, 442 A output. Active production. Frame R11, IP22, NEMA 1. 380-415 V 3-phase input. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"SCIP":"9ECED1FE-316A-4BF4-991E-2606BB5FE13A Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R11","Power Factor":"1","Sound dB (A)":"77 dB(A)","Analog Inputs":"2","Frequency (f)":"48 ... 63 Hz","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The low-harmonic drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.d).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 415 V","Degree of Protection":"IP22","Apparent Power Output":"306 kV·A","Communication Protocol":"CAN","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 2pcs, 3V, 220mAh, 6g","Number of Digital In/Outputs":"7 / 5","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"250 kW","Output Current, Normal Use (In)":"442 A","Output Power, Heavy-Duty Use (PhD)":"200 kW","Output Current, Heavy-Duty Use (IhD)":"363 A","Output Power, Light-Overload Use (PlD)":"250 kW","Output Current, Light-Overload Use (IlD)":"420 A","Technical UL/Output Power, Normal Use (UL)":"- Hp","Technical UL/Output Current, Normal Use (UL)":"- A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000146024","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000146024/alternatives.json"},"ai":{"faq":[{"question":"What are the key power ratings for this drive?","answer":"Normal-use output is 250 kW at 442 A. Heavy-duty output is 200 kW at 363 A. Light-overload output is 250 kW at 420 A. Apparent power output is 306 kV·A."},{"question":"What input voltage and frequency does it require?","answer":"It requires 380–415 V three-phase input at 48–63 Hz."},{"question":"What is the enclosure rating and frame size?","answer":"Frame size R11, IP22 degree of protection, NEMA Type 1 enclosure."},{"question":"What compliance documentation is available for this drive?","answer":"The SCIP number is 9ECED1FE-316A-4BF4-991E-2606BB5FE13A Finland, covering EU REACH/SCIP requirements. The drive is exempt from EU ecodesign energy efficiency requirements under Regulation EU/2019/1781 §2.3.d as a low-harmonic drive."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000146024","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000146024 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}