{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000146109","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000146109","canonicalUrl":"https://aoctrl.com/abb/3AXD50000146109","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000146109","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-37 series, 3AXD50000146109, 250 kW normal-use output, 414 A, R11 frame, IP22, 380-500 VAC 3-phase input.","salesMarkdown":"The 3AXD50000146109: The drive carries three duty curves. Normal use (Pn) delivers 250 kW at 414 A continuous — that's the number for a centrifugal pump or fan with a standard torque profile. Heavy-duty use (PhD) drops to 200 kW at 361 A, sized for constant-torque loads like a conveyor or extruder that need full torque across the speed range. Light-overload use (PlD) matches the normal-use power at 250 kW but current is 393 A, a middle ground for applications with moderate overload cycles. The UL heavy-duty rating is 300 Hp at 361 A and light-overload is 350 Hp at 414 A. R11 frame — expect a cabinet footprint sized for a drive this class, with IP22 ingress protection (finger-safe, no dripping water). Maximum ambient is 40 °C, altitude derating starts above 1000 m. Operating humidity 5 to 95% non-condensing. Sound level is 77 dB(A) — not silent, but within range for a 250 kW drive in a machine room. The enclosure is NEMA Type 1 for indoor use. ## I/O and control interface Onboard I/O: 2 analog inputs, 2 analog outputs, 7 digital inputs, 5 digital outputs. Communication is CAN — no onboard Industrial Ethernet. The drive includes the control unit. For fieldbus connectivity beyond CAN, you'd add an optional adapter module. The battery pack (two CR2032 lithium coins) backs the real-time clock and parameter storage. SCIP number 9ECED1FE-316A-4BF4-991E-2606BB5FE13A Finland is on file for EU waste and substance reporting. The drive is exempt from EU ecodesign efficiency requirements (Regulation EU/2019/1781, §2.3.d) because it's a low-harmonic type. WEEE category 4 — large equipment. No additional compliance documents (RoHS, REACH, UL) are listed in the spec record, but the UL duty ratings confirm UL listing for the heavy-duty and light-overload power levels.","metaTitle":"3AXD50000146109 ABB ACS880-37-0414A-5 Drive, 250 kW, 414 A,","metaDescription":"Active ABB ACS880-37 drive, 3AXD50000146109. 250 kW normal use, 414 A output, IP22, R11 frame. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"SCIP":"9ECED1FE-316A-4BF4-991E-2606BB5FE13A Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R11","Power Factor":"1","Sound dB (A)":"77 dB(A)","Analog Inputs":"2","Frequency (f)":"48 ... 63 Hz","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The low-harmonic drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.d).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP22","Apparent Power Output":"359 kV·A","Communication Protocol":"CAN","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 2pcs, 3V, 220mAh, 6g","Number of Digital In/Outputs":"7 / 5","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"250 kW","Output Current, Normal Use (In)":"414 A","Output Power, Heavy-Duty Use (PhD)":"200 kW","Output Current, Heavy-Duty Use (IhD)":"361 A","Output Power, Light-Overload Use (PlD)":"250 kW","Output Current, Light-Overload Use (IlD)":"393 A","Technical UL/Output Power, Normal Use (UL)":"- Hp","Technical UL/Output Current, Normal Use (UL)":"- A","Technical UL/Output Power, Heavy-Duty Use (UL)":"300 Hp","Technical UL/Output Current, Heavy-Duty Use (UL)":"361 A","Technical UL/Output Power, Light-Overload Use (UL)":"350 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"414 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000146109","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000146109/alternatives.json"},"ai":{"faq":[{"question":"What are the key output ratings for this drive?","answer":"Normal-use output is 250 kW at 414 A. Heavy-duty use is 200 kW at 361 A. Light-overload use is 250 kW at 393 A. UL heavy-duty is 300 Hp at 361 A, and UL light-overload is 350 Hp at 414 A."},{"question":"What is the input voltage and frequency range?","answer":"380 to 500 VAC three-phase, 48 to 63 Hz."},{"question":"What enclosure and protection rating does it have?","answer":"IP22 ingress protection, NEMA Type 1 enclosure, frame size R11."},{"question":"Does this drive have an Industrial Ethernet interface?","answer":"No. The onboard communication protocol is CAN. There are zero Industrial Ethernet hardware interfaces on this variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000146109","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000146109 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}