{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000158119","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000158119","canonicalUrl":"https://aoctrl.com/abb/3AXD50000158119","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000158119","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-37 series drive, order code 3AXD50000158119, 90 kW normal-use power, 156 A normal-use current, 380...500 V 3-phase input.","salesMarkdown":"The ABB 3AXD50000158119 is an ACS880-37-0156A-5 low-harmonic drive rated for 90 kW normal-use output (Pn) and 156 A normal-use current (In) on a 380...500 V three-phase supply. Heavy-duty use (PhD) is 75 kW with 124 A output (IhD); light-overload use (PlD) stays at 90 kW but draws 148 A (IlD). Apparent power output is 135 kV·A, which helps size the upstream transformer or generator. Frame size R8 sets the panel cutout and mounting footprint. ## Heavy-duty vs normal-use headroom The heavy-duty current (124 A) is lower than the normal-use current (156 A). The UL listing for heavy-duty use (100 Hp, 124 A) matches the IEC heavy-duty rating. ## Integration notes Enclosure is NEMA Type 1 with IP22 protection — suitable for indoor, non-condensing environments. Ambient temperature limit is 40 °C; altitude ceiling is 1000 m. Onboard communication is CAN — no Industrial Ethernet port. Digital I/O: 7 inputs, 5 outputs. Analog I/O: 2 inputs, 2 outputs. The control unit is included. Sound level is 70 dB(A) — factor that into panel layout if the drive sits near operator stations. The SCIP number (9ECED1FE-316A-4BF4-991E-2606BB5FE13A) is registered in Finland.","metaTitle":"ABB 3AXD50000158119 ACS880-37 Drive, 90 kW, 156 A","metaDescription":"ABB ACS880-37-0156A-5 drive, 90 kW normal use, 156 A output, 380-500 V 3-phase. Active production, sourced to order. Frame R8, IP22, CAN onboard.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"SCIP":"9ECED1FE-316A-4BF4-991E-2606BB5FE13A Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R8","Power Factor":"1","Sound dB (A)":"70 dB(A)","Analog Inputs":"2","Frequency (f)":"48 ... 63 Hz","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","Analog Outputs":"2","lifecycle_stage":"current","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Ecodesign Exemption":"Energy efficiency data is not provided for the drive. The low-harmonic drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.d).","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP22","Apparent Power Output":"135 kV·A","Communication Protocol":"CAN","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"Lithium Coin, CR2032, 2pcs, 3V, 220mAh, 6g","Number of Digital In/Outputs":"7 / 5","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"90 kW","Output Current, Normal Use (In)":"156 A","Output Power, Heavy-Duty Use (PhD)":"75 kW","Output Current, Heavy-Duty Use (IhD)":"124 A","Output Power, Light-Overload Use (PlD)":"90 kW","Output Current, Light-Overload Use (IlD)":"148 A","Technical UL/Output Power, Normal Use (UL)":"- Hp","Technical UL/Output Current, Normal Use (UL)":"- A","Technical UL/Output Power, Heavy-Duty Use (UL)":"100 Hp","Technical UL/Output Current, Heavy-Duty Use (UL)":"124 A","Technical UL/Output Power, Light-Overload Use (UL)":"125 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"156 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000158119","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000158119/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this drive?","answer":"Normal-use output is 90 kW at 156 A; heavy-duty output is 75 kW at 124 A. Input is 380–500 V three-phase, 48–63 Hz. Apparent power rating is 135 kV·A."},{"question":"What enclosure protection does it have?","answer":"The drive carries NEMA Type 1 and IP22 ratings, making it suitable for indoor installations where dripping water or falling dirt is unlikely."},{"question":"What communication protocols are onboard?","answer":"The drive includes CAN communication. It has no Industrial Ethernet interface."},{"question":"What is the SCIP number and where is it registered?","answer":"The SCIP number is 9ECED1FE-316A-4BF4-991E-2606BB5FE13A, registered in Finland."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000158119","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000158119 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}