{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000161867","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000161867","canonicalUrl":"https://aoctrl.com/abb/3AXD50000161867","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000161867","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580 drive control unit, frame size R1, 0.55 kW / 3.7 A normal use, 200-240 V 3-phase, MODBUS, IP20, 3AXD50000161867.","salesMarkdown":"## Drive control unit for the ACS580 The ABB 3AXD50000161867 is a drive control unit rated 0.55 kW output at 3.7 A normal use, on a 200–240 V three-phase supply. It sits in the R1 frame size and includes the control unit itself — no additional options module required for basic operation. Communication is MODBUS over the built-in interface; there are 5 digital inputs, 2 digital outputs, 2 analog inputs, and 1 analog output on board. Three load profiles are defined: light-overload use (PlD) at 0.55 kW / 3.5 A, normal use (Pn) at 0.55 kW / 3.7 A, and heavy-duty use (PhD) at 0.37 kW / 2.4 A. The light-overload and normal ratings overlap at 0.55 kW, but the current difference (3.5 vs 3.7 A) reflects the thermal headroom for occasional overloads. For UL-listed installations, the heavy-duty output is 0.5 Hp at 2.4 A, and light-overload is 0.75 Hp at 3.5 A. This is an active catalog item — no LTB or phase-out window. It is the control unit only; the power stage and any option modules are ordered separately. For a BOM freeze, the key fit check is the motor current against the heavy-duty rating (2.4 A) for continuous torque, or the normal-use rating (3.7 A) if the load profile is variable torque. The MODBUS interface is fixed; there is no second protocol slot, so if the network requires PROFINET or EtherNet/IP, this unit will not bridge it without an external gateway.","metaTitle":"ABB 3AXD50000161867 ACS580 drive control unit, 0.55 kW, 3.7","metaDescription":"ABB 3AXD50000161867 ACS580 drive control unit, 0.55 kW normal use output, 3.7 A, 200-240 V 3-phase, MODBUS, IP20, R1 frame. Current lifecycle stage. RoHS/REACH compliant. Sourced t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"483516f7-5042-4d76-a918-d7fab20a54ce Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R1","Power Factor":"0.98","Sound dB (A)":"63.10 dB(A)","Standby Loss":"14 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"1","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP20","Apparent Power Output":"1.5 kV·A","Communication Protocol":"MODBUS","Power Consumption (@Pcons)":"57 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"5 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"0.55 kW","Output Current, Normal Use (In)":"3.7 A","Output Power, Heavy-Duty Use (PhD)":"0.37 kW","Output Current, Heavy-Duty Use (IhD)":"2.4 A","Output Power, Light-Overload Use (PlD)":"0.55 kW","Certificates and Declarations/RoHS Date":"20230303","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"3.5 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"0.5 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"2.4 A","Technical UL/Output Power, Light-Overload Use (UL)":"0.75 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"3.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000161867","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000161867/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive control unit?","answer":"The SCIP number is 483516f7-5042-4d76-a918-d7fab20a54ce Finland."},{"question":"What compliance documentation is available?","answer":"RoHS compliance per EU Directive 2011/65/EU and amendment 2015/863, dated 2023-03-03. REACH declaration confirms substances above 0.1% mass as of 2025-09-05. UL ratings are provided for heavy-duty (0.5 Hp, 2.4 A) and light-overload (0.75 Hp, 3.5 A) use."},{"question":"What is the maximum operating altitude?","answer":"Rated for altitudes up to 1000 m without derating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000161867","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000161867 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}