{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000161904","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000161904","canonicalUrl":"https://aoctrl.com/abb/3AXD50000161904","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000161904","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580 drive control unit, R1 frame, 200–240 V 3-phase input, 2.2 kW / 9.8 A normal-duty output, MODBUS, IP20, open type.","salesMarkdown":"The ABB 3AXD50000161904 is the control unit for a general-purpose drive, R1 frame size. It handles a 3-phase 200–240 V input and delivers 2.2 kW normal-duty output at 9.8 A. The unit includes the control board and firmware; the power stage is a separate module. Communication is MODBUS via the built-in port — no Ethernet interface on this variant. Light-overload (9.3 A) suits variable-torque fans and centrifugal pumps. The normal-duty 9.8 A rating is for standard variable-torque applications with occasional overload. Standby loss is 15 W, sound level 63.1 dB(A), and efficiency meets IE2. Ambient temperature max is 50 °C; altitude rated to 1000 m without derating. Enclosure is IP20 open type — panel-mount only, no standalone floor use. The control unit includes 2 analog inputs, 1 analog output, 5 digital inputs, and 2 digital outputs. Humidity range 5–95% non-condensing. No battery inside — no periodic replacement.","metaTitle":"ABB 3AXD50000161904 ACS580 Drive Control Unit, R1, 2.2 kW","metaDescription":"ABB 3AXD50000161904 ACS580 drive control unit, R1 frame, 2.2 kW normal-duty output at 9.8 A, MODBUS, active production, RoHS/REACH compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"483516f7-5042-4d76-a918-d7fab20a54ce Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R1","Power Factor":"0.98","Sound dB (A)":"63.10 dB(A)","Standby Loss":"15 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"1","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP20","Apparent Power Output":"3.9 kV·A","Communication Protocol":"MODBUS","Power Consumption (@Pcons)":"140 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"5 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"2.2 kW","Output Current, Normal Use (In)":"9.8 A","Output Power, Heavy-Duty Use (PhD)":"1.5 kW","Output Current, Heavy-Duty Use (IhD)":"7.8 A","Output Power, Light-Overload Use (PlD)":"2.2 kW","Certificates and Declarations/RoHS Date":"20230303","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"9.3 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"2 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"7.5 A","Technical UL/Output Power, Light-Overload Use (UL)":"2 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"9.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000161904","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000161904/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive control unit?","answer":"SCIP number 483516f7-5042-4d76-a918-d7fab20a54ce Finland is registered for this part under EU waste framework."},{"question":"What compliance documentation is available?","answer":"RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863 (date 2023-03-03). REACH declaration confirms substances >0.1% (date 2025-09-05). UL technical ratings are also listed for heavy-duty and light-overload use."},{"question":"What are the key output ratings?","answer":"Normal-duty: 2.2 kW at 9.8 A. Heavy-duty: 1.5 kW at 7.8 A. Light-overload: 2.2 kW at 9.3 A. UL heavy-duty: 2 Hp at 7.5 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000161904","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000161904 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}