{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000162017","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000162017","canonicalUrl":"https://aoctrl.com/abb/3AXD50000162017","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000162017","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580 drive module, 3AXD50000162017, 3 kW normal-use / 2.2 kW heavy-duty, 200–240 V 3-phase, MODBUS, IP20, Frame R2.","salesMarkdown":"The 3AXD50000162017: For North American installations, UL listings match the heavy-duty output at 3 Hp / 9.3 A and light-overload at 3 Hp / 11.6 A, so the drive fits UL 508A panels without derating surprises. The module includes 5 digital inputs and 2 digital outputs, plus 2 analog inputs and 1 analog output — enough for basic process control without an expansion I/O module. Communication is via MODBUS, so it integrates with most PLCs over RS-485. No Industrial Ethernet interface is onboard; if you need PROFINET or EtherNet/IP, you will add an optional fieldbus adapter. Maximum ambient temperature is 50 °C, with operating humidity from 5 to 95% RH. The 1000 m altitude rating is standard; above that, derate current per the drive manual. Standby loss is 15 W, and sound level is 58.8 dB(A) — noticeable in a quiet control room but typical for an R2 frame.","metaTitle":"ABB 3AXD50000162017 ACS580 Drive Module, 3 kW Normal Use","metaDescription":"ABB 3AXD50000162017 ACS580 drive module, 3 kW normal-use output (12.2 A), 2.2 kW heavy-duty (9.8 A). 200–240 V 3-phase, MODBUS, IP20, current lifecycle stage. RoHS/REACH compliant.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"171cbe90-f958-4bba-b9dd-e62c0f6b4011 Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R2","Power Factor":"0.98","Sound dB (A)":"58.80 dB(A)","Standby Loss":"15 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"1","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP20","Apparent Power Output":"4.9 kV·A","Communication Protocol":"MODBUS","Power Consumption (@Pcons)":"149 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"5 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"3 kW","Output Current, Normal Use (In)":"12.2 A","Output Power, Heavy-Duty Use (PhD)":"2.2 kW","Output Current, Heavy-Duty Use (IhD)":"9.8 A","Output Power, Light-Overload Use (PlD)":"3.0 kW","Certificates and Declarations/RoHS Date":"20230303","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"11.6 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"3 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"9.3 A","Technical UL/Output Power, Light-Overload Use (UL)":"3 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"11.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000162017","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000162017/alternatives.json"},"ai":{"faq":[{"question":"What is the SCIP number for this drive module?","answer":"The SCIP number is 171cbe90-f958-4bba-b9dd-e62c0f6b4011 Finland, registered for EU waste reporting under WEEE Category 5 (Small Equipment)."},{"question":"What compliance documentation is available for 3AXD50000162017?","answer":"RoHS compliance follows EU Directive 2011/65/EU and Amendment 2015/863 (date 2023-03-03). REACH declaration confirms substances above 0.1 mass percentage (date 2025-09-05). UL listings cover heavy-duty and light-overload ratings for North American installations."},{"question":"What are the key ratings for this drive?","answer":"Normal-use output is 3 kW at 12.2 A; heavy-duty output is 2.2 kW at 9.8 A; light-overload output is 3.0 kW at 11.6 A. Input is 200–240 V 3-phase, 47.5–63 Hz. Efficiency is IE2, power factor 0.98."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000162017","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000162017 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}