{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000162031","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000162031","canonicalUrl":"https://aoctrl.com/abb/3AXD50000162031","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000162031","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580 drive control unit, 3AXD50000162031, R3 frame, 5.5 kW / 25.0 A normal duty, MODBUS RTU, IP20, current lifecycle.","salesMarkdown":"## Output Ratings and Duty Selection The 3AXD50000162031: The normal-duty (light-overload) line is 5.5 kW / 25.0 A, which matches the heavy-duty line at 4.0 kW / 17.5 A for applications with higher peak demand. The UL listing mirrors these: 7.5 Hp light-overload at 24.2 A, and 5 Hp heavy-duty at 16.7 A. The apparent power output is 10 kV·A, and the power factor sits at 0.98. Standby loss is 24 W, so the unit idles efficiently when the motor is stopped. ## I/O and Mounting The control unit provides 2 analog inputs and 1 analog output, plus 5 digital inputs and 2 digital outputs. No battery is included or required. Mounting is module-style, likely onto the R3 power stage or backplane. The unit draws 398 W power consumption at rated load. Altitude rating is 1000 m without derating; higher installations need to account for reduced cooling. The sound level is 65.8 dB(A), which is moderate for an R3 frame drive.","metaTitle":"ABB 3AXD50000162031 ACS580 Drive Control Unit, R3 Frame, 5.5","metaDescription":"ABB 3AXD50000162031 ACS580 drive control unit, R3 frame, 5.5 kW normal duty, MODBUS RTU, IP20. Current lifecycle stage. RoHS/REACH/UL compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"cb415b59-4237-4c11-b542-bb9f3de4d187 Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R3","Power Factor":"0.98","Sound dB (A)":"65.80 dB(A)","Standby Loss":"24 W","Analog Inputs":"2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"1","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP20","Apparent Power Output":"10 kV·A","Communication Protocol":"MODBUS","Power Consumption (@Pcons)":"398 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"5 / 2","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"5.5 kW","Output Current, Normal Use (In)":"25.0 A","Output Power, Heavy-Duty Use (PhD)":"4.0 kW","Output Current, Heavy-Duty Use (IhD)":"17.5 A","Output Power, Light-Overload Use (PlD)":"5.5 kW","Certificates and Declarations/RoHS Date":"20230303","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"24.2 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"5 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"16.7 A","Technical UL/Output Power, Light-Overload Use (UL)":"7.5 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"24.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000162031","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000162031/alternatives.json"},"ai":{"faq":[{"question":"What are the key output ratings for this drive control unit?","answer":"Normal-duty (light-overload) output is 5.5 kW at 25.0 A; heavy-duty output is 4.0 kW at 17.5 A. UL ratings are 7.5 Hp at 24.2 A (light-overload) and 5 Hp at 16.7 A (heavy-duty)."},{"question":"What compliance documentation is available for this part?","answer":"RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863 (date 20230303), REACH declaration with substances >0.1% (date 20250905), and UL listing for both heavy-duty and light-overload ratings. The SCIP number is cb415b59-4237-4c11-b542-bb9f3de4d187 Finland."},{"question":"What communication protocol does this unit support?","answer":"MODBUS RTU over the built-in serial port. There are no industrial Ethernet interfaces on this variant."},{"question":"What is the frame size and mounting type?","answer":"Frame size R3, mounting type is module. The enclosure is IP20, open-type per NEMA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000162031","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000162031 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}