{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3AXD50000162130","brand":"ABB","brandSlug":"abb","productSlug":"3AXD50000162130","canonicalUrl":"https://aoctrl.com/abb/3AXD50000162130","factsUrl":"https://aoctrl.com/api/mcp/products/3AXD50000162130","rawCanonicalId":null},"summary":{"shortDescription":"ABB drive module, frame size R2, 3-phase 200–240 V input, 3 kW / 12.2 A normal-use output, IP20, CAN interface, IE2 efficiency.","salesMarkdown":"## Integrator's note on this drive module The ABB 3AXD50000162130 is a 3-phase drive module in frame size R2, rated for a 200–240 V input bus and delivering 3 kW / 12.2 A in normal-duty use. Heavy-duty output drops to 2.2 kW / 9.8 A, light-overload holds at 3.0 kW / 11.6 A. The module includes the control unit and communicates over CAN — there is no onboard industrial Ethernet, so plan for a gateway if your network is PROFINET or EtherNet/IP. Digital I/O is 2 inputs / 1 output; analog channels are absent. Efficiency lands at IE2, standby loss is 15 W. Ambient limit is 50 °C, enclosure is IP20 open type. Heavy-duty (PhD) at 2.2 kW / 9.8 A covers constant-torque applications — conveyors, extruders — where the drive sees sustained peak current. Light-overload (PlD) at 3.0 kW / 11.6 A is a short-time rating for occasional overloads; the drive can deliver this for a defined period before folding back. Match your motor's full-load amps to the heavy-duty current curve for reliable starting and thermal protection. Module mounting — frame R2 — fits a standard backplate or DIN-rail adapter (not included). Ambient temperature max 50 °C. Altitude limit is 1000 m without derating. Humidity range 5–95% non-condensing. Sound level is 58.80 dB(A). Standby loss of 15 W adds to panel heat load.","metaTitle":"ABB 3AXD50000162130 Drive Module, R2 Frame, 3 kW / 12.2 A","metaDescription":"ABB drive module, frame size R2, 3-phase 200–240 V input, 3 kW normal-use output at 12.2 A, IP20, CAN interface, IE2 efficiency. Active production. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"SCIP":"171cbe90-f958-4bba-b9dd-e62c0f6b4011 Finland","Altitude":"1000 m","Includes":"Control unit","Frame Size":"R2","Power Factor":"0.98","Sound dB (A)":"58.80 dB(A)","Standby Loss":"15 W","Analog Inputs":"0","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Analog Outputs":"0","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 50 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"200 ... 240 V","Degree of Protection":"IP20","Apparent Power Output":"4.9 kV·A","Communication Protocol":"CAN","Power Consumption (@Pcons)":"149 W","Operating Humidity (RHamβ)":"5 ... 95","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"2 / 1","Number of Hardware Interfaces":"Industrial Ethernet 0","Output Power, Normal Use (Pn)":"3 kW","Output Current, Normal Use (In)":"12.2 A","Output Power, Heavy-Duty Use (PhD)":"2.2 kW","Output Current, Heavy-Duty Use (IhD)":"9.8 A","Output Power, Light-Overload Use (PlD)":"3.0 kW","Certificates and Declarations/RoHS Date":"20230303","Certificates and Declarations/REACH Date":"20250905","Output Current, Light-Overload Use (IlD)":"11.6 A","Certificates and Declarations/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Technical UL/Output Power, Heavy-Duty Use (UL)":"3 Hp","Certificates and Declarations/REACH Information":"True - contains substances > 0.1 mass percentage","Technical UL/Output Current, Heavy-Duty Use (UL)":"9.3 A","Technical UL/Output Power, Light-Overload Use (UL)":"3 Hp","Technical UL/Output Current, Light-Overload Use (UL)":"11.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3axd50000162130","alternativesUrl":"https://aoctrl.com/api/mcp/products/3AXD50000162130/alternatives.json"},"ai":{"faq":[{"question":"What are the key output ratings for this drive?","answer":"Normal-use output is 3 kW / 12.2 A; heavy-duty output is 2.2 kW / 9.8 A; light-overload output is 3.0 kW / 11.6 A. UL ratings are 3 Hp at 9.3 A (heavy-duty) and 11.6 A (light-overload)."},{"question":"What communication protocol does this module support?","answer":"It uses CAN as the onboard fieldbus. There are no industrial Ethernet interfaces — a gateway is needed for PROFINET or EtherNet/IP networks."},{"question":"What compliance documentation is available?","answer":"RoHS compliance per EU Directive 2011/65/EU (declaration date 20230303) and REACH declaration (date 20250905) stating substances above 0.1% mass. UL listing covers heavy-duty and light-overload use."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3AXD50000162130","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3AXD50000162130 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}